期刊文献+

电磁耦合传感器在检测XLPE电缆局部放电中的应用 被引量:1

Application of the Electromagnetic Coupling Sensors in Detecting Partial Discharges in XLPE Cable
下载PDF
导出
摘要 比较了声测法、差分法、电容传感器法、方向耦合传感器法、阻抗检测法和电磁耦合法在检测XLPE电缆局部放电中的优缺点,认为电磁耦合法更适合用于XLPE电缆局部放电的在线检测,并对电磁耦合传感器的研究情况进行了综述。 The advantages and the disadvantages of the methods used in detecting partial discharges in XLPE cable are compared, namely they are the acoustic method, the differential method, the capacitive sensors method, the directional coupling sensors method, the impedance detection method and the electromagnetic coupling method, the electromagnetic coupling method is considered suitable for partial discharges detection in XLPE cable, and the research status of electromagnetic coupling sensors is summarized.
出处 《华北电力技术》 CAS 2007年第11期47-51,共5页 North China Electric Power
关键词 电磁耦合 局部放电检测 传感器 electromagnetic coupling partial discharge detection sensor
  • 相关文献

参考文献25

  • 1M Ekberg, A Gustafsson, M Leijon, et al. Recent Results in HV Measurement Techniques [J]. IEEE Transactions On Dielectrics and Electrical Insulation, 1995, 2(5):906-913.
  • 2L E Lundgaard, W Hansen. Acoustic Method for Quality Control and In--service Periodic Monitoring of Medium Voltage Cable Terminations [ C ]. IEEE Internationla Symposium on Electrical Insulation, Virginia USA, 1998:130-133.
  • 3Y Tian, P L Lewin, A E Davies, et al. Comparison of On-line Partial Discharge Detection Methods for HV Cable Joints [J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2002, 9(4) :604-615.
  • 4D pommerenke, T Strehl, R Heinrich, W Kalkner, et al. Discrimination between Internal PD and Other Pulses Using Directional Coupling Sensors on HV Cable Systems [J]. IEEE Transactions on Dielectrics and Electrical Insulation, 1999, 6(6): 814-824.
  • 5A J Brown. Condition Monitoring of HV Electrical Rotating Plant On-line Partial Discharge Technitques. IEE Tutorial - AEA Capenhurst Apr. 99.
  • 6Y Tian, P L. Lewin, J S Wilkinson, et al. Optically Based Partial Discharge Continuous Monitoring System for HV Cable Joints[C] IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2004: 21-24.
  • 7D Wenzel, U Schichler, H Borsi and E Gockenbach. Recognition of Partial Discharge on Power Units by Directional Coupling [C]. International Symposium on HV, ISH 1994, 5626-1-5626-4, Vol. 5, Graz, Austria, 1994.
  • 8E Pultrum. On-site Testing of Cable Systems after Laying, Monitoring with HF Partial Discharge Detection [C] IEE Two day Colloquium on Supertension (66-500 kV). Polymeric Cables and their Accessories, IEE Digest No. 1995/210, 21, Nov. 1995.
  • 9N H Ahmed, N N Srinivas. On-line Partial Discharge Detection in Cables [C]. IEEE Conference on Electrical Insulation and Dielectrics Phenomena, pp. 214- 217, Minneapolis, Oct. 19-22, 1997.
  • 10E Pultrum and M J M van Riet. HF Partial Discharge Detection in HV Extruded Cable Accessories [J]. Proceedings Of Jicable, pp. 662-665.

二级参考文献35

  • 1陈庆,李红斌,张明明,刘延冰.采用主副印制电路板构造的Rogowski线圈性能分析及设计[J].电力系统自动化,2004,28(16):79-82. 被引量:34
  • 2李红斌,刘延冰,张明明.电子式电流互感器中的关键技术[J].高电压技术,2004,30(10):4-6. 被引量:35
  • 3王海明,郑绳楦,刘丰.高压电子电流互感器Rogowski线圈优化设计[J].高电压技术,2005,31(9):5-7. 被引量:9
  • 4Ginzo Katsuta, Atsushi Toya, Keiichi Muraoka, et al, Development of a method partial discharge detection in extra-high voltage cross-linked polyethylene insulated cable lines[J]. IEEE Trans on Power Delivery, 1992. 7(3): 1068-1074
  • 5Wenzel D, Schichler U, Borsi H, et al. Recognition of partial discharges on power units by directional coupling[C]. The 9th ISH. Austria, 1995,5626: 1-4
  • 6Borsi H, G-ockenbach E, Schichler U. Monitoring of partial discharges (PD) in high voltage cables[C] The 8th ISH. Japan, 1993: 173-176
  • 7Wouters P A A F, Vanderlaan P C T, Hetzel E, et al. New on-ine partial discharge measurement technique for polymer insulated cables and accessories[C]. The 8th ISH. Japan, 1993:105-108
  • 8IEC60270. Partial discharge measurements[S], 1981
  • 9Ahmed N H, srinivas N N. On-line partial discharge detection in cables [J]. IEEE Trans on D & El, 1998, 5(2) : 181-188
  • 10Kojovic L. Rogowski Coils Suit Relay Protection and Measurement [J]. IEEE Computer Applications in Power,1997, 10(3): 47-52.

共引文献42

同被引文献13

  • 1韦斌,王伟,李成榕,李信,李华春.VHF钳型传感器在线检测110kV XLPE电缆局放[J].高电压技术,2004,30(7):37-39. 被引量:34
  • 2吴倩,刘毅刚,李熙谋.高压交联聚乙烯电缆绝缘老化检测技术调研[J].电力设备,2005,6(7):40-45. 被引量:18
  • 3杨连殿,朱俊栋,孙福,黄国强,杨兰均,张乔根.振荡波电压在XLPE电力电缆检测中的应用[J].高电压技术,2006,32(3):27-30. 被引量:62
  • 4谢安生,郑晓泉,李盛涛,G Chen.XLPE电缆绝缘中的电树枝结构及其生长特性[J].高电压技术,2007,33(6):168-173. 被引量:42
  • 5YANG J J,ZHANG D M.Partial discharge phenomena due to electrical treeing in XLPE[C]//Conference on Industrial Electronics and Applications.[S.l.]:IEEE,2006:1-6.
  • 6BOGGS S,DENSLEY J.Fundaments of partial discharge in the context of field cable testing[J].IEEE Electrical Insulation Magazine,2000,16(25):13-18.
  • 7CAVALLINI A,MONTANARI G C.A new methodology for the identification of PD in electrical apparatus:properties and applications[J].IEEE Transactions on Dielectrics and Electrical Insulation,2005,12(2):203-213.
  • 8CAVALLINI A,MONTANARI G C.A fuzzy logic algorithm to detect electrical trees in polymeric insulation systems[J].IEEE Transactions on Dielectrics and Electrical Insulation,2005,12(6):1134-1144.
  • 9MEIJER S,JONGEN R A,GULSKI E,et al.VHF partial discharge detection during after-laying testing of power cables[C]//2007 International Conference on Solid Dielectrics.Winchester,UK:IEEE,2007:544-547.
  • 10VAKILIAN M,BLACKBURN T R,JAMES R E,et al.Semiconducting layer as an attractive PD detection sensor of XLPE cables[J].IEEE Transactions on Dielectrics and Electrical Insulation,2006,13(4):885-891.

引证文献1

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部