期刊文献+

基于“一线总线”的冻结法温度监测系统 被引量:16

Temperature Monitoring System for Freezing Method Based on "1-wire Bus"
下载PDF
导出
摘要 冻结法施工中,地层温度是判断冻结壁的厚度、平均温度和强度等性能的重要依据,盐水温度是反映冻结系统状态的重要指标,是冻结法施工中必须实时监测的基本数据。由于测点数量众多、位置分散,一种布线简单、维护方便的数字化温度监测系统十分必要。采用计算机作上位机,LTM-8000系列"一线总线"智能模块作下位机,数字温度传感器DS18B20作测温元件,设计出一种全数字化的基于"一线总线"的冻结法温度监测系统。该系统具有现场布线方便、适应恶劣的施工环境、易于扩展、自动化数据采集等特点。 In construction by freezing method, soil temperature is a key parameter to estimate the wall thickness, average temperature and strength of the frozen soil, and the brine temperature is an important factor to reflect the state of the freezing system. Thus the soil and brine temperature are essential data to be monitored in real time. With plentiful monitoring points and their dispersive location, a fully digital temperature monitoring system based on 1 -wire bus is carried out with a host computer, intelligent "1 -wire bus" modules of LTM -8000 series as the slave units and digital thermometer DS18B20 as the temperature sensors. Having advantage such as simple distribution in site, high adaptability to the abominable surroundings, easy extensibihty and automatic data collection, . etc, the system is effective for temperature monitoring in freezing method.
出处 《地下空间与工程学报》 CSCD 2007年第5期937-940,共4页 Chinese Journal of Underground Space and Engineering
基金 国家自然科学基金资助项目(50578120)
关键词 “一线总线”数字温度传感器 冻结法 1 -wire Bus digital temperature sensor freezing method
  • 相关文献

参考文献6

二级参考文献27

  • 1尚丽平,张淑清,史锦珊.光纤光栅传感器的现状与发展[J].燕山大学学报,2001,25(2):139-143. 被引量:24
  • 2余永权.Flash单片机原理及应用 [M].北京:电子工业出版社,1997..
  • 3Sonali Banerjee,Chung-en Zah,Rajaram Bhat ,et al.Fiber Optic Photoluminescence Setup for Spatially Resolved Measurements[J].IEEE.Transactions on Instrumentation and Measurement,1999,48(1):45-48.
  • 4Tomasz R Wolinski,Aleksandra Jarmolik,Wojtek J Bock.Development of Fiber Optic Liquid Crystal Sensor for Pressure Measurement[J].IEEE. Transactions on Instrumentation and Measurement,1999,48(1):2-5.
  • 5Tomasz R Wolinsk,Andrzej W Domanski,Witold Konopka,et al.Prototype Fiber Optic Liquid Crystalline Sensor for Pressure Monitoring[J].IEEE.Transactions on Instrumentation and Measurement,1999,48(3):684-687.
  • 6Giovanni Betta,Antonio Pietrosanto. An Intrinsic Fiber Optic Temperature Sensor[J]. IEEE.Transactions on Instrumentation and Measurement,2000,49(1):25-28.
  • 7Giovanni Betta,Antonio Pietrosanto, Antonio Scaglione.Temperrature Measurement by Multifiber Optical Sensor[J]. IEEE.Transactions on Instrumentation and Measurement,2000,49(5):1004-1007.
  • 8Dils R R.High-temperature optical fiber thermometer[J].Journal of Applied Physics,1983,54(3):1198-1203.
  • 9Cavaleiro P M,Lobo Ribeiro A B.Reference Technique for Intensify-based Sensors Using Fiber Bragg Gratings[J].Electronics Letters,1995,31(5):392393.
  • 10Davis C M .光纤传感器技术手册[M].北京:电子工业出版社,1987.

共引文献46

同被引文献86

引证文献16

二级引证文献113

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部