对混凝土搅拌站骨料称量系统的两种主要结构称量不精确的原因进行了分析,并对“皮带累积计量”结构进行了三次改进,介绍了一种“超称扣减”称量结构,从而提高搅拌站骨料计量精度.
The authors analyzes the causes of inaccurate measurement weighing of two main structures and three - time improvements of the strap cumulative metering structure. A new measurement has been introduced to increase aggregate measure accuracy in the concrete mixing stations.