期刊文献+

基于PIC单片机控制的同步发电机励磁电源监控系统 被引量:1

Monitoring and Control System for Excitation Power of Synchronous Generator Based on PIC
下载PDF
导出
摘要 结合陇南某水电站的实际情况,设计了同步发电机励磁电源实时运行状态监控系统。该系统以PIC16F877单片机为核心构成实时状态监控单元,以监测励磁电压和励磁电流,并通过RS-485串行通信的方式将监测信息传给上位机,同时上位机可以发送控制命令到单片机,通过改变整流电路的触发角以达到调节励磁电压的目的。这套系统目前已经在陇南某水电站投入运行,实践表明该系统运行稳定可靠,具有调节精度高和响应速度快的特点。 A real-time operating state monitoring and control system was designed, combined with the real conditions of the water and electricity power station in Longnan. This system is constructed with single-chip PIC16F877 as its core.The monitoring informations such as excitation voltage and excitation current are uploaded to master computer via RS - 485 serial communication bus. The master computer can also send control informations to single-chip, in order to change the trigger angle, then to control the excitation voltage. This system has been used in the water and electricity power station in Longnan. The operating results show that it has good stability, high control accuracy and fast response speed.
出处 《仪表技术与传感器》 CSCD 北大核心 2007年第12期46-49,共4页 Instrument Technique and Sensor
基金 甘肃省自然科学基金资助项目(3ZS042-B25-001)
关键词 PIC单片机 励磁电源 异步串行通信 D/A转换 single-chip PIC excitation power asynchronous serial communication D/A change
  • 相关文献

参考文献5

二级参考文献14

  • 1王仲文.精通串行口通信[M].北京:电子工业出版社,1994..
  • 2Noel Jerke 姜静波等(译).Visual Basic实用程序集粹[M].电子工业出版社,1994..
  • 3.DataSheet of TDC—GP1[M].德国ACAM公司出版,2000..
  • 4.DS1820单总线数字温度计[M].北京:北京大地泰河科技发展有限公司,..
  • 5冯冬青.模糊智能控制[M].北京:化学工业出版社,2000.75-93.
  • 6Noel Jerke,Visual Basic实用程序集粹,1994年
  • 7王仲文(译),精通串行通信,1994年
  • 8.DataSheet of TDC-GP1[Z].德国ACAM公司出版,2000..
  • 9.DS1820单总线数字温度计[Z].北京:北京大地泰河科技发展有限公司,..
  • 10陶晓农.分散式变电站监控系统中的通信技术方案[J].电力系统自动化,1998,22(4):51-54. 被引量:39

共引文献29

同被引文献6

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部