期刊文献+

双区加热法蒸汽湿度探针内水滴汽化长度的数值计算 被引量:1

Numerical Calculation of Water Drop Vaporization Length in Double-region-heating Steam Wetness Probe
下载PDF
导出
摘要 基于双区加热法蒸汽湿度探针的热力学基本原理和计算模型,针对汽轮机典型运行工况,计算了探针内的水滴汽化长度数据。计算中干蒸汽采用连续相标准湍流模型,水滴相采用离散相模型,边界条件为恒热流;分别计算了相同壁面热流不同水滴直径和相同水滴直径不同壁面热流2种情况下水滴的汽化长度,获得了水滴汽化长度、水滴直径和壁面热流密度之间的定量关系。直径相同的水滴。其汽化长度与壁面热流密度呈指数相关;壁面热流密度恒定时,水滴直径与汽化长度呈线性相关。 Based on the thermodynamic principle and calculation model of double-region-heating steam wetness probe, according to the typical operating condition of steam turbine, the water drop vaporization length in the double-regionheating steam wetness probe has been numerically calculated. The continuous dry steam is simulated by standard turbulence model, the water drop is simulated by discrete phase model and the wall is used constant heat flux boundary condition. The corresponding relations between the water drop vaporization length and wall heat flux and water drop diameters have been obtained. The calculation result has a guidance significance for the design of the double-region-heating steam wetness probe.
出处 《电站辅机》 2007年第4期10-13,共4页 Power Station Auxiliary Equipment
关键词 双区加热法 蒸汽 湿度 离散 模型 汽化 长度 计算 double-region-heating steam wetness discreteness model vaporization length calculation
  • 相关文献

参考文献4

二级参考文献30

  • 1苏海林,蔡小舒,J.Messner,G.Eyb.试验汽轮机末级内湿蒸汽流动特性的实验研究[J].中国电机工程学报,2004,24(9):257-261. 被引量:15
  • 2Moore M J, Sieverding C H. Two-phase steam flow in turbines and separators[M]. London: HemispherePublishing Corporation,1976.
  • 3YangS R, WangJ G, ChenF etal. Automatic wetness fraction monitoring for wet steam flow[C]. Proc of 11th IFAC World Congress. Tallinn, Estonia, 1990. 176-179.
  • 4Downie B,Polymeropoulos C,Gogos G.Interaction of a water mist with a buoyant methane diffusion flame[J].Fire Safety Journal,1995,24(4):359 ~ 381
  • 5Nam S.Numerical-simulation of actual delivered density of sprinkler spray through fire plumes[J].Atomization and Sprays,1994,4(4):385 ~ 404
  • 6Bill R G.Numerical-simulation of actual delivered density(Add) measurements[J].Fire Safety Journal,1993,20(3):227 ~ 240
  • 7Yoon S S,et al.Numerical modeling and experimental measurements of a high speed solid-cone water spray for use in fire suppression applications[J].International Journal of Multiphase Flow,2004,30(11):1369~ 1388
  • 8Parra T,et al.Extinction of premixed methane-air flames by water mist[J].Fire Safety Journal,2004,39(7):581~600
  • 9Hua J S,et al.A numerical study of the interaction of water spray with a fire plume[J].Fire Safety Journal,2002,37(7):631 ~ 657
  • 10Kim S C,Ryou H S.The effect of water mist on burning rates of pool fire[J].Journal of Fire Sciences,2004,22(4):305 ~ 323

共引文献53

同被引文献5

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部