期刊文献+

用多个能量探测方法校正层析γ扫描透射图像重建中射线线衰减系数 被引量:3

THE METHOD OF MULTI-ENERGY GAMMA RAYS TO RECTIFY LINEAR ATTENUATION COEFFICIENT IN IMAGE RECONSTRUCTION OF TOMOGRAPHIC GAMMA RAY SCANNING
下载PDF
导出
摘要 对采用多个能量探测方法来校正层析γ扫描透射图像重建中射线线衰减系数进行了初步探讨。应用蒙特卡洛方法计算了18种材料在不同能量下的γ射线线衰减系数,并拟合得出当物质材料和密度确定时γ射线的线衰减系数与能量的关系,从而重建出不同能量下的透射图像。 Multi-energy method to rectify the linear attenuation coefficients in transmitted image reconstruction by tomographic gamma ray scanning was preliminarily explored. The gamma ray linear attenuation coefficients for different energies were calculated using Monte Carlo method for 18 different kinds of materials. The relationship between ray linear attenuation coefficient and energy was fitted for given material and density, so as to reconstruct transmitted image for different energies.
出处 《辐射防护》 CAS CSCD 北大核心 2008年第1期24-28,共5页 Radiation Protection
基金 国家自然科学基金资助项目(项目编号:10675084)
关键词 层析γ扫描 多能γ射线 线衰减系数 透射图像重建 Tomographic Gamma Ray Scanning, Multi-Energy Gamma Rays, Linear Attenuation Coefficient, Transmitted Image Reconstruction
  • 相关文献

参考文献5

  • 1Estep R J,et al.Tomographic gamma scanning to assay heterogeneous radioactive waste.Nuclear Science and Engineering,1994.118:145
  • 2Venkataraman R,Croft S,Villani M,et al.The next generation tomographic gamma scanner.The ESARDA Annual Symposium on Safeguards and Nuclear Material Management.London,UK,May 10 ~ 12,2005
  • 3肖雪夫,夏益华,吕峰,李泽.用于固体放射性废物无损定量测量的TGS图象重构技术[J].辐射防护,2001,21(1):1-10. 被引量:14
  • 4潘京全.γ射线的线性吸收系数拟合[J].中华放射医学与防护杂志,1998,18(5):362-364. 被引量:4
  • 5李德平,潘自强,主编.辐射防护手册·第一分册.北京:原子能出版社,1987.278

二级参考文献11

  • 1王经瑾.大型集装箱辐射检测系统[J].现代物理知识,1996,8(5):20-24. 被引量:1
  • 2赵俊.图象分块重构及基于组合滤波器的卷积法的研究(硕士论文)[M].杭州:浙江大学,1990..
  • 3金彦武.工业CT样品台自动控制系统的设计(硕士论文)[M].中科院上海原子核所,1992..
  • 4潘苏,辐射防护,1989年,9卷,3期,195页
  • 5李德平,辐射防护手册.第1分册,1987年,278页
  • 6马崇智,放射性同位素手册,1979年,451页
  • 7王经谨,现代物理知识,1996年,8卷,5期,20页
  • 8金彦武,硕士学位论文,1992年
  • 9赵俊,硕士学位论文,1990年
  • 10肖雪夫,吕峰,刘大鸣.蒙特卡罗方法选择 TGS 准直器的最佳形状[J].原子能科学技术,1998,32(3):201-207. 被引量:5

共引文献16

同被引文献104

  • 1GB9133-1995.放射性废物的分类[S].[S].,..
  • 2Martz HE, Azevedo SG, Roberson GP, et al. Considerations for an active and passive scanner to assay nuclear waste drums, UCRL-JC-105265[R]. Lawrence Livermore National Laboratory, 1990.
  • 3Lawrence livermore national laboratory. Award-winning system assays radioactive waste with radiation[EB/OL]. (2007-11-8)[2014-3-27]. https://www, llnl. gov/str/Roberson, html.
  • 4Prettyman TH, Reilly TD, Miller MC, et al. Advances in nuclear instrumentation for safeguards, LA-UR-96-3757ER]. Los Alamos National Laboratory, 1996.
  • 5Stewart JE, Walton RB, Phillips JR, et al. Measurement and accounting of the minor actinides produced in nuclear power reactors, LA-13054MS, UC-7OO[R]. Los Alamos National Laboratory, 1996.
  • 6Camp DC, Martz HE, Roberson GP, et al. Nondestructive waste-drum assay for transuranic content by Gamma-ray active and passive computed tomography[J]. Nuclear Instruments and Methods in Physics Research A, 2002, 495: 69-83.
  • 7Estep RJ, Prettyman TH, Sheppard GA. Tomographic Gamma scanning to assay heterogeneous radioactive waste[J]. Nuclear Science and Engineering, 1994, 118: 145-152.
  • 8Martin R, Jones DF, Parker JL. Gamma-ray measurements with the segmented Gamma scanner, LA-7059-M[R]. Los Altos Scientific Laboratory, 1977.
  • 9Estep RJ. Assay of heterogeneous radioactive wastes by low-resolution tomographic Gamma scanning[R]. Transactions of American Nuclear Society, 1990, 62(178).
  • 10Kawasaki S, Kondo M, lzumi S, et al. Radioactivity measurement of drum package waste by a computed-tomography technique[J]. International Journal of Radiation Applications and Instrumentation, Part A, Applied Radiation and Isotopes, 1990, 41(10/11): 983-987.

引证文献3

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部