摘要
从HFRP加固砖砌体双剪试件的受力模型入手,从理论上分析试件的加固受力机理,推导抗剪承载力计算公式,并进行芳纶纤维复合材料(AFRP)加固砖砌体双剪试件的验证性试验研究。结果表明,所推导的理论计算公式与试验结果吻合较好。并得出影响AFRP布加固砖砌体抗剪极限承载力的主要因素是:有效发挥系数γ、摩擦系数μ和AFRP布条带轴线与灰缝方向的夹角θ。
It takes from the force model of masonry wall double shear specimen strengthened with AFRP, and analyzes it' s reinforcement mechanism, then deduces the compute formula of the shear-resistant, and takes a validation study of double shear specimen. The results express that the calculation formula has good accordance with the experiment results. It gets the main factors that influence the ultimate shear-resistant of masonry wall strengthened with AFRP: valid exertive coefficient γ, coefficient of friction μ, the included anger of the AFRP axis and the mortar joint 8.
出处
《建筑结构》
CSCD
北大核心
2007年第12期83-86,104,共5页
Building Structure
基金
国家863计划资助项目(2001AA336010)
关键词
芳纶纤维复合材料
砖砌体
加固
抗剪
抗剪承载力
aramid fiber reinforced plastics
masonry wall
reinforcement
shear
shear resistant