期刊文献+

电感耦合等离子体质谱法同时测定地下水中硼溴碘 被引量:30

Simultaneous Determination of Boron,Bromine and Iodine in Groundwater Samples by Inductively Coupled Plasma-Mass Spectrometry
下载PDF
导出
摘要 建立了电感耦合等离子体质谱法同时测定地下水中B、Br、I的方法。选定φ=2%(体积分数)的稀NH3·H2O介质消除碘的记忆效应。采用干扰较少的^10B和^79Br同位素。B、Br,I在0~10000ng/mL呈良好的线性关系。方法的检出限为^10B 0.176ng/mL,^79Br 0.876ng/mL,^127I 0.132ng/mL;精密度(RSD,n=12)为^10B 2.86%,^79Br 3.36%,^127I 2.69%;^10B的阶梯加标回收率为94.6%~101.5%,^79Br为98.3%~104.9%,^127I为96.5%~102.0%。 A method for the determination of boron, bromine and iodine in groundwater samples by inductively coupled plasma-mass spectrometry (ICP-MS) was proposed. Weak ammonia solution (φ =2% ) was selected to eliminate the memory effect from iodine. The isotopes of ^10B and ^79Br were chosen as determination isotopes for the less interference from coexistent elements. Linearity of boron, bromine and iodine are in 0 - 10000 ng/mL The detection limits of the method for ^10B, ^79Br and ^127I are 0. 176 ng/mL, 0. 876 ng/mL and 0. 132 ng/mL respectively. The recoveries of the method are 94.6% - 101.5% for B, 98.3% - 104.9% for Br and 96.5% 102.0% for I with precision (RSD,n = 12) of 2.86% for B, 3.36% for Br and 2.69% for I.
出处 《岩矿测试》 CAS CSCD 2008年第1期25-28,共4页 Rock and Mineral Analysis
关键词 电感耦合等离子体质谱法 地下水 inductively coupled plasma-mass spectrometry boron bromine iodine groundwater
  • 相关文献

参考文献18

二级参考文献93

共引文献365

同被引文献1614

引证文献30

二级引证文献202

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部