期刊文献+

污秽绝缘子泄漏电流特性研究 被引量:75

Review on Leakage Current Characteristics of Contamination Insulators
下载PDF
导出
摘要 为提高泄漏电流评估绝缘子污秽度的可靠性,综述了污秽绝缘子泄漏电流特性问题20余年的研究成果,其内容包括临闪前泄漏电流和污闪电压的关系;在运行电压下及绝缘子表面污层饱和受潮时泄漏电流和放电现象间的关系;泄漏电流和等值附盐密度(ESDD)、绝缘子形状、片数、污秽状况以及污闪电压的关系;以及在绝缘子表面污层未达到饱和受潮条件时泄漏电流和雾浓度、相对湿度、ESDD间关系的研究。基于泄漏电流与其他污秽度参数之间关系的研究开发出在实验室及变电站测量多参量泄漏电流的仪器,并在现场测量了大量泄漏电流及气象条件的数据。根据研究成果提出了利用运行电压下的泄漏电流最大值进行污闪预警的方法。 This paper summarizes the results achieved on the research of leakage current characteristics of external insulation in Tsinghua University for more than 20 years. The relationship between leakage current at pre-flashover stage and the flashover voltage is developed. When the insulator surfaces are saturated with moisture, the relation ship between leakage current under service voltage and discharge phenomenon is studied. The influences such as equivalent salt deposit density (ESDD), the flashover voltages, the profile and string length of the insulators and the applied voltage on the leakage current under service voltage are investigated. When the surfaces are not saturated with moisture, the ESDD level, the fog density and relative humidity (RH) are related to the maximum leakage current (IL,m). A multi-channel leakage current monitoring system adequate for both the lab and the substation was developed. A large number of leakage current and meteorological data have been recorded by this system. Finally, the method to predict flashover by maximum leakage current under service voltage is developed based on the above results.
出处 《高电压技术》 EI CAS CSCD 北大核心 2008年第1期1-6,共6页 High Voltage Engineering
基金 国家自然科学基金(50377020)~~
关键词 绝缘子 泄漏电流 沿面放电 污闪 等值附盐密度 相对湿度 insulator leakage current surface discharge pollution flashover ESDD relative humidity
  • 相关文献

参考文献15

  • 1关志成,王绍武,梁曦东,王黎明,范炬.我国电力系统绝缘子污闪事故及其对策[J].高电压技术,2000,26(6):37-39. 被引量:118
  • 2Mao Yingke, Guan Zhicheng, Wang Liming, et al. Investigation of leakage current of outdoor insulators with a newly developed monitoring system[C]. Proceedings of the 14th International Symposium on High Voltage Engineering. Beijing, China, 2005: 26-29.
  • 3Mao Yingke, Guan Zhicheng, Wang Liming, et al. Development of a multi channel leakage current monitoring system for the outdoor insulators[C]. International Conference on Condition Monitoring and Diagnosis. Changwon, Korea, 2006: 2-5.
  • 4张仁豫,关志成,薛家麒,朱德恒,谈克雄.Discharge along a contaminated dielectric surface[J].Progress in Natural Science:Materials International,1995,5(4):13-22. 被引量:2
  • 5关志成,张仁豫,朱德恒.染污绝缘子临闪时泄漏电流和闪络电压之间关系的研究[R].北京:清华大学,1981:11-19.
  • 6张仁豫 朱德恒 关志成.自然染污与人工染污绝缘子的闪络电压与泄漏电流间关系的研究.电工技术学报,1984,2(12):1-5.
  • 7关志成 张仁豫.染污绝缘子在交流电压下的污闪条件分析.清华大学学报,1986,26(3):30-39.
  • 8Guan Zhicheng, Zhang Renyu. A study of parameters to express the pollution severity of insulators[C]. Proceedings of ICPST Session RA. Beijing, China, 1991.
  • 9Guan Zhicheng, Zhang Renyu. Calculation of DC and AC flashover voltage of polluted insulators[J]. IEEE Trans on EI, 1990, 5(4): 723-729.
  • 10Zhicheng Guan, Ying Dong, Goushun Cui. The method to assess the withstand voltage of polluted insulator[C]. 9th International Symposium on High Voltage Engineering. Graz, Austria, 1995.

二级参考文献15