期刊文献+

脑微透析探针置入对透析样品的影响 被引量:6

Influence of Glutamate Levels in Rat Striatum after Intracerebral Implantation of Microdialysis Probe
下载PDF
导出
摘要 目的探讨微透析探针置入的刺激对大鼠纹状体内谷氨酸水平的影响。方法通过初次和二次置入微透析探针至大鼠纹状体并收集脑微透析液,结合高效液相色谱法检测透析液谷氨酸水平。结果探针初次置入纹状体谷氨酸水平立即升高约30倍,3h后降至基础值;二次置入时谷氨酸仅升高约15倍,1h后即降至基础值。结论微透析探针置入的刺激可引起大鼠纹状体内谷氨酸水平短暂增高,在脑微透析检测谷氨酸样品时应注意探针置入的影响。 Objective To investigate the influence of glutamate levels in rat striatum after intracerebral implantation of microdialysis probe. Methods Microdialysis probe was inserted into rat striatum by one-time or two-time insertions. Dialysate was collected and detected for glutamate levels with high performance liquid chromatograph(HPLC). Results The insertion of microdialysis probe into striatum at first time results in a transient raise in glutamate(about 30-fold above baseline), and declined to baseline within 3 hours. While glutamate levels were increased only 15-fold above baseline when microdialysis probe reinsert into striatum, and dropped to baseline within 1 hour. Conclusion The data suggest that the implant trauma may cause transient glutamate perturbations in rat striatum. Thus, the influence of probe implantation for detecting glutamate samples by. intracerebral microdialysis need to be considered.
出处 《福建医科大学学报》 2008年第1期46-48,共3页 Journal of Fujian Medical University
基金 福建省自然科学基金资助项目(C0310022) 福建省科学研究发展基金资助项目(FJGXY04010)
关键词 微透析 谷氨酸 高效液相色谱 brain microdialysis glutamic acid chromatography,high performance liquid
  • 相关文献

参考文献11

  • 1Bungay P M,Newton-Vinson P,Isele W,etal. Mierodialysis of dopamine interpreted with quantitative model incorporating probe implantation trauma[J]. J Neurochem, 2003,86 (4) :932-946.
  • 2Orlowska-Majdak M,Traezyk W Z,Szymaski D. Hippoeampal vasopressin release evoked by N-methyl-D-aspartate (NMDA) microdialysis[J]. Physiol Res, 2003,52(3) :373-382.
  • 3deLange E C, Danhof M, Zurcher C,et al. Repeated microdialysis perfusions: periprobe tissue reactions and BBB permeability[J]. Brain Res, 1995,702(1-2) :261-265.
  • 4包新民 舒斯云.大鼠脑立体定位图谱[M].北京:人民卫生出版社,1990.25-28.
  • 5Orlowska-Majdak M. Microdialysis of the brain structures: application in behavioral research on vasopressin and oxytocin [J]. Acta Neurobiol Exp (Wars), 2004,64 (2) : 177-188.
  • 6Westergren I,Nystr? m B, H amberger A,et a l. Intracerebral dialysis and the blood-brain barrier[J]. J Neurochem, 1995, 64(1) :229-234.
  • 7Horn T F, Engelmann M. In vivo microdialysis for nonapeptides in rat brain:a practical guide[J]. Methods, 2001,23(1): 41-53.
  • 8Reynolds N C Jr, Lin W, Cameron C M,et al. Extraeellular perfusion of rat brain nuclei using mierodialysis: a method for studying differential neurotransmitter release in response to neurotoxins[J]. Brain Res Brain Res Protoc , 1999,4(2) : 124- 131.
  • 9Chaurasia C S, M ller M, Bashaw E D, et al. AAPS-FDA workshop white paper: microdialysis principles, application and regulatory perspectives [J]. Pharm Res, 2007,24 (5) : 1014-1025.
  • 10Bellander B M, Cantais E,Enblad P,et al. Consensus meeting on microdialysis in neurointensive care[J]. Intensive Care Med, 2004,30(12):2166-2169.