期刊文献+

微型种植体支抗在内收前牙正畸治疗中的临床应用 被引量:44

Clinical application of mini-screw implant anchorage for anterior teeth retraction orthodontic treatment
下载PDF
导出
摘要 目的评价微螺钉种植体在正畸治疗中作为支抗内收前牙的有效性。方法选择双颌前突和上颌前突的患者共19例,应用上、下颌后牙区微螺钉种植体作为支抗内收前牙。在治疗前后拍摄头颅定位侧位片,以SN为基准重叠治疗前、后头影测量描记图,观察第一磨牙的位置改变。治疗结束后观察患者前牙覆覆盖关系和Ⅱ类磨牙关系的改变,以及面型凸度的改善程度。结果19例患者中16例患者应用微螺钉种植体支抗顺利完成正畸治疗,均建立了正常的前牙覆覆盖关系,成功纠正了Ⅱ类磨牙关系,面型凸度明显改善,第一磨牙位置稳定。结论国产微螺钉种植体支抗与传统的强支抗方式相比,确保磨牙支抗不丧失的能力更强,几乎达到绝对支抗的能力,可以实现理想的支抗控制。 Objective To evaluate the efficiency of mini-screw implants as orthodontic anchorage for anterior teeth retraction in orthodontics treatment. Methods Nineteen patients with maxillary or bimaxillary protrusion were selected, and they were treated with mini-screw implants as anchorage for anterior teeth retraction. The sides of cephalometric roent-genogram were taken at the beginning and the end of the treatment. Taking SN as oriteri- on, overlap the pictures of cephalometrics were taken at the beginning and the end of the treatment, and the movements of the first molar were observed. Exchanges of the anterior overbite and overjet, Class Ⅱ molar relationship and the improvements of facial symmetry were observed after the treatment. Results Among the nineteen patients, sixteen successfully complished the orthodontics treatment. They all set up correct relationship of overbite and overjet and successfully rectified the Class Ⅱ molar relationship. Facial symmetry obviously improved and the first molar remained stable. Conclusion Compared with the traditional strong anchorage, the homemade mini-screw implant anchorage is stronger for the molar anchorage, with which the ideal anchorage contral could be achieved.
出处 《国际口腔医学杂志》 CAS 2008年第1期5-6,共2页 International Journal of Stomatology
基金 河北省张家口市科技局省级科学技术研究与发展指导计划基金(062761609)
关键词 微螺钉种植体 正畸支抗 内收前牙 mini-screw implant orthodontic anchorage retract anterior teeth
  • 相关文献

参考文献4

二级参考文献9

  • 1Deguchi T, Yamamoto TT, Kanomi R, et al . The use of small titanium screws for orthodongtic anchorage[J]. J Den Res, 2003, 82(5): 377- 381.
  • 2Gapski R, Wang HL, Mascarenhas P, et al. Critical review of immediate implant loading[J]. Clin Oral Impl Res, 2003, 14(5):515 -527.
  • 3Brunski JB. Biomechanical factors affecting bone-dental implant interface[J]. Clin Mater, 1992, 10(3): 153-201.
  • 4Park HS. A new protocol of the sliding mechanics with Micro-Implant Anchorage(M.I.A)[J]. Korea J Orthod, 2000, 30(6): 677-685.
  • 5Roberts WE, Smith RK, Zilberman Y, et al. Osseous adaptation to continuous loading of rigid endosseous implants [ J ]. Am J Orthod,1984, 86(2): 95-111.
  • 6Haanaes HR. Implants and infections with special reference to oral bacterial[J]. J Clin Periodontol, 1990, 17(7): 516-524.
  • 7Park HS. The skeletal cortical anchorage using titanium microscrew implants[J]. Kor J Orthod, 1999, 29(6): 699 - 706.
  • 8Roberts WE, Helm FR, Marshall KJ, et al. Rigid endosseous implants for orthodontic and orthopedic anchorage [ J ]. Angle Orthod,1989, 59(4): 247 - 256.
  • 9马俊青,王林,王震东,张卫兵,严斌,李青奕.微型支抗种植体稳定性的动物实验研究[J].口腔医学,2004,24(1):13-15. 被引量:45

共引文献107

同被引文献264

引证文献44

二级引证文献377

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部