摘要 研究小尺度或微区的同位素组成变化已成为地球化学分析技术发展的重要方向之一。在研制CO2激光熔蚀氧同位素制样装置的基础上,通过该装置与MAT-253质谱计联机实现了硅酸盐和氧化物矿物的氧同位素在线分析。所测样品包括NBS-28石英标样、石英玻璃,以及天然的石榴子石、锆石、橄榄石等一些难熔矿物。该装置分析的颗粒样品氧同位素分析精度为±0.22‰,最低样品量为8μmol的O2;石英玻璃原位分析的氧同位素分析精度为±0.35‰,最低样品量为7μmol的O2。这种装置和分析方法具备速度快,熔样温度高的特点,尤其适于难熔矿物。该装置可采用脉冲激光实现石英玻璃的微区原位分析,可应用于单个矿物生成环带的氧同位素研究。 The determination of isotopic composition in trace amount has become one of the major directions of development of isotopic measurements. A laser extraction system has been assembled successfully and combined with MAT-253 mass spectrometer to form a laser analytical system in this study, And the method of analyzing oxygen isotope of silicates and oxides was development. Research objects are some typical eutexia and refractory minerals, including international standard material NBS-28, quartz glass, garnet, zircon and olivine, focusing on the homogeneity and variation of oxygen isotopic composition in trace amount. The analytical precision of particle samples is ±0.22‰, and its oxygen contents for analysis are reduced to 8μMol. The analytical precision of in-situ quartz glass is ±0.35‰, and its oxygen contents for analysis are reduced to 7μMol. With this method, we can analyze very small amounts of materials with high spatial resolution, and it is also characterized by fast analytical rate and high melt temperature, especially for refractory minerals. The method can be used to investigate oxygen isotope zonation, trace amount variations on oxygen isotopic composition and oxygen isotope geochemistry in single mineral, and shows great applications about natural minerals, rocks and mantle inclusions forming conditions and the origin.
出处 《地质论评》 CAS CSCD 北大核心 2008年第1期139-144,共6页 Geological Review
关键词 激光熔蚀 BrF5法氧同位素分析 硅酸盐和氧化物 microprobe analysis oxygen isotope silicates and oxides
  • 相关文献

参考文献30

二级参考文献55

  • 1龚冰,郑永飞,赵子福,赵彦冰.硅酸盐和金属氧化物矿物氧同位素组成的CO_2激光氟化分析[J].矿物岩石地球化学通报,2001,20(4):428-430. 被引量:13
  • 2郑淑蕙.稳定同位素地球化学[M].北京:北京大学出版社,1986..
  • 3[1]C1ayton R N, Mayeda T K. The use of bromine penta-fiuoride in the extraction of oxygen fiom oxides and silicates for isotopic analysis[J].G eochim. Comochim. Acta, 1963, 27: 43-52.
  • 4[2]Sharp Z D. A laser-based microanalytical method for the in situ determination of oxygen isotope ratios of silicates and oxides[J]. Geochim.Cosmochim. Acta, 1990, 54: 1353- 1357.
  • 5[3]Sharp Z D. In situ laser microprobe techniques for stable isotope analy sis[J]. Chem. Geol., 1992, 101: 3- 20.
  • 6[4]Rumble D, Farquhar J, Young E D, Christensen C P. In situ oxygen isotope analysis with an excimer laser using F12 and BrF5 reagents andO2 gas as analyte[J]. Geoehim. Cosmochim. Acta, 1997, 61: 4229- 4234.
  • 7[5]Valley J W, Kitchen N, Kohn M J, et al. UWG-2, a garnet standard for oxygen isotope ratio: strategies for high precision and accuracy with laserheating[J]. Geochim. Cosmochim. Acta, 1995, 59:5223- 5231.
  • 8SHARP Z D, ONEIL J R. A laser-based carbon reduction technique for oxygen isotope analysis of silicates and oxides[J]. Carnegie Inst Washington, Yearbk, 1988, 89: 72-78.
  • 9SMALLEY P C, STIJFHOORN D E, RAHEIM A, et al. The laser microprobe and its application to the study of C and O isotopes in calcite and aragonite[J]. Sediment Geol, 1989, 65: 211-221.
  • 10CROWE D E, VALLEY J W. Laser microprobe study of sulfur isotope variation in a sea-floor hydrothermal spire, Axial Seamount, Juan de Fuca Ridge, eastern Pacific[A]. HARMON R S, HINTON R W. Frontiers in Isotope Geosciences[M]. Chem Geol (Isotope Geosciences), 1992, 101:63-70.

共引文献60

同被引文献168

引证文献11

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部