期刊文献+

基于SVM和ECT的两相流离散相浓度测量 被引量:2

ECT and SVM based concentration measurement of two-phase flow
下载PDF
导出
摘要 利用12电极电容层析成像系统(ECT)传感器和最小二乘支持向量机(LS-SVM),提出了两相流离散相浓度测量的新方法。电容传感器用来获取反应离散相分布的66个电容测量值。LS-SVM用来建立离散相浓度测量模型,模型的输入是66个独立的电容值,输出是离散相浓度值。本方法省去了传统ECT技术测量浓度时的图像重建过程。实验结果表明:该方法是有效的,测量误差在6%以内。 Based on 12-electrode Electrical Capacitance Tomography (ECT) sensor and Least Squares Support Vector Machine (LS-SVM),a new method for phase concentration measurement of two-phase flow was proposed. ECT sensor was used to obtain the 66 capacitance values,which reflected the phase distribution.LS-SVM was applied to establish the model for phase concentration measurement of two-phase flow.In this model,66 capacitance values were the inputs and the concentration was the output.This new method implemented direct concentration measurement of two-phase flow without the need of time-consuming image reconstruction.The experimental results show that it is effective and the measurement error is within 6%.
出处 《自动化与仪器仪表》 2008年第2期72-74,共3页 Automation & Instrumentation
基金 甘肃省自然科学基金(编号:3ZS062-B25-016) 兰州交通大学"青蓝"人才资助项目
关键词 两相流 最小二乘支持向量机 浓度 电容 Two-phase flow Least Squares Support Vector Machine (LS-SVM) Concentration Electrical capacitance
  • 相关文献

参考文献8

  • 1李海青.两相流检测技术及其应用[M].杭州:浙江大学出版社,1991.
  • 2Huang Z Y, Wang B L and Li H Q. Dynamic Voidage Measurements in a Gas Solid Fluidized Bed by Electrical Capacitance Tomography[J]. Chemical Engineering eommu nieations, 2003, 190(10): 1395-1410
  • 3张淳,彭黎辉,姚丹亚,张宝芬.采用改进的PCA算法测量两相流相浓度[J].清华大学学报(自然科学版),2003,43(3):400-401. 被引量:6
  • 4王保良,黄志尧,陈珙,李海青.两相流离散相浓度软测量新方法研究[J].浙江大学学报(工学版),2001,35(1):62-66. 被引量:3
  • 5V. N. Vapnik, Statistical Learning Theory [M]. New York: Wiley, 1998
  • 6Cao L J and Tay F E H. Support Vector Machine with Adaptive Parameters in Financial Time Series Forecasting [J]. IEEE Transa ctions on neural networks, 2003, 14(6): 1506-1518
  • 7Suykens J A K, Vandcwalle J. Least Squares Support Vector Mac hint Classifiers [J]. Neural Processing Letters, 1999, 9(3): 290 - 301
  • 8Suykens J A K, Gestel T V, Bmbanter J D, and et al. Least Squares Support Vector Machine [M]. Singapore: World Scienti fic Press, 2002

二级参考文献9

  • 1沈清 胡德文 时春.神经网络应用技术[M].北京:国防科技大学出版社,1993..
  • 2ZHANG Yuchun,PENG Lihui,ZHANG Baofen,et al. Principal component analysis based concentration measuring for two-phase flow [A]. Proceedings of the 3rd International Symposium on Measurement Techniques for Multiphase Flows [C]. Japan: The Japanese Society for Multiphase Flow,2001. 227-230.
  • 3ZOU Lu,ZHANG Yuchun,PENG Lihui,et al. Using principal component analysis to measure two-phase flow concentration [A]. Proceedings of 2nd World Congress on Industrial Process Tomography [C]. Hannover,Germany,2001. 35-40.
  • 4Mohamad-Saleh J,Hoyle B S,Podd F J W,et al. Direct flow process estimations from tomographic data using artificial neural systems [A]. Proceedings of 2nd World Congress on Industrial Process Tomography [C]. Hannover,Germany,2001. 751-758.
  • 5Mohamad-Saleh J,Hoyle B S,Podd F J W,et al. Direct process estimations from tomographic data using artificial neural systems [J]. Journal of Electronic Imaging,2001,10(3): 646-652.
  • 6Xie C G, Stott A L, Plaskowaski A, et al. Design of capacitance electrodes forconcentration measurement of two-phase flow[J]. Measurement Science & Technology, 1990,1: 65- 78.
  • 7Sami M. The use of capacitance sensor for percentage determination in multiphasepipelines[J]. IEEE Trans Instrum Mesa, 1980, Im-29(1) :24-27.
  • 8Huang S M, Plaskowski A B, Xie C G, et al. Tomography imaging of two-component flowusing capacitance sensors[J]. J Phys E:Sci Instrum, 1989,22:173-177.
  • 9Songming Huang, Robert G Green, Andrzej Plaskowski, et al. A high frequencystray-immune capacitance transducer based on the charge transfer principle[J]. IEEE Transon Instrum and Mesa, 1988,37(3):368-373.

共引文献8

同被引文献13

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;