期刊文献+

中频电刺激波的分析与设计 被引量:2

Analysis and design of intermediate-frequency stimulation wave
下载PDF
导出
摘要 为增强中频电子治疗仪的物理功能、分离治疗阈值与疼痛阈值,有效地克服机体适应性等问题,针对FNS(fastigial nucleus stimulation)&SCS(spinal cord stimulation)模块进行分析,根据频谱分析和自相关分析方法设计了一种用随机信号调幅的中频微分型指数信号作为电刺激的波形,它不仅能分离治疗阈值与疼痛阈值,而且也能解决对机体的适应性问题。 To enhance physical function of intermediate-frequency treatment instrument, separate treatment and pain threshold, and overcome adaptability to body, we analyzed FNS&SCS (fastigial nucleus stimulation and spinal cord stimulation) modules, and designed a kind of intermediate-frequency exponential pulse stimulation wave with amplitude modulated by random signal based on spectrum analysis and autocorrelation analysis. This wave can separate treatment and pain thresholds, and overcome the adaptability to body effectively.
作者 张台平
出处 《中国组织工程研究与临床康复》 CAS CSCD 北大核心 2008年第13期2470-2472,共3页 Journal of Clinical Rehabilitative Tissue Engineering Research
  • 相关文献

参考文献7

二级参考文献4

共引文献38

同被引文献18

  • 1林岳军,杨建伟,谭维溢.中频交变电流刺激的最佳频率[J].国外医学(物理医学与康复学分册),2005,25(4):146-147. 被引量:4
  • 2芳菲.常用的低频、中频电疗法[J].医疗保健器具,2006(10):39-41. 被引量:7
  • 3罗均,邢兰兴,周焱,谢少荣.C8051F020的微型旋翼飞行器实验平台的控制系统[J].光学精密工程,2007,15(5):713-718. 被引量:5
  • 4LAZAROS L, ATHANASIOS K, IOANNIS L, et al. Effects of intensity transeutaneous electrical nerve stimulation (TENS) on pressure pain threshold and blood pressure in healthy humans [J]. Clin J Pain, 2009, 25(9) : 773-780.
  • 5CHEN C C, JOHNSON M I. An investigation into the effects of frequency-modulated transcutaneous electrical nerve stimulation (TENS) on experimentally-induced pressure pain in healthy hu- man participants [J]. J Pain, 2009, 10(10): 1029-1037.
  • 6JONES D H, KILGOUR R D, COMTOIS A S. Test-retest reliability of pressure pain threshold measure of the upper limb and torso in young healthy women [J]. J Pain, 2007, 8 (8) : 650-656.
  • 7EDWARDS R R, SARLANI E, WESSELMANN U, et al. Quantitative assessment of experimental pain pereeption: multiple domains of clinical relevance [J]. Pain, 2005, 114 (3) : 315-319.
  • 8ZIMKOWSKI M M, LINDI.EY E M, PATEL V V, et al. De- sign and evaluation of a computer-controlled pressure algometer[J]. J Med Devices, 2011, 5(3) : 031002-1-031002-6.
  • 9Tiktinsky R, Chen L, Narayan P. Electrotherapy : yesterday, today and tomorrow[ J]. Haemophilia,2010,16 ( Suppl. 5).
  • 10Kesar T, Chou L W, Binder-Macleod S A. Effects of stimula- tion frequency versus pulse duration modulation on muscle fatigue[ J ]. Journal of Electromyography and Kinesiology, 2008,18(4).