期刊文献+

箱包DR/SSCT检查系统图像重建算法研究

Research on Image Reconstruction of DR/SSCT Security Inspection System
下载PDF
导出
摘要 在箱包DR(Digital Radiography)/CT安全检查系统基础上,开发了箱包DR/SSCT(single slicespiral CT)检查系统,该系统可改善原系统检测客体耗时和漏检方面的缺点。研究工作分为更改数据采集系统和设计SSCT重建算法两部分,分别在模拟实验和物理实验中比较了各种SSCT重建算法的重建效果,并利用探测器数据插值提高重建图像质量。通过实验对照,本系统采用了360°LI(Linear Inter-polation)和JH-HI(Jiang Hsieh-Half scan Interpolation)加权重建算法。 On the basis of DR (Digital Radiography)/CT security inspection system, DR/SSCT (single slice spiral CT) security inspection system was developed. This spiral CT system can improve the CT system's drawbacks. The research work includes in replacing the former data acquisition system by a new system which can acquire projection data of multi-slices and devising the SSCT reconstruction algorithms. Simulation experiments and practical experiments were devised to contrast several algorithms. Interpolation technique was operated in detectors data in order to improve the algo-rithms. In conclusion, the system exploits an algorithm of weighted average of 360°LI (Linear Interpolation) and JH-HI (Jiang Hsieh-Half scan Interpolation).
作者 李建 丛鹏
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2008年第4期348-352,共5页 Atomic Energy Science and Technology
关键词 SSCT 图像重建 线性插值 SSCT image reconstruction linear interpolation
  • 相关文献

参考文献8

  • 1RIGAUTS H, MARCHAL G, BAERT A L, et al. Initial experience with volume scanning[J]. Journal of Computer Assisted Tomography, 1990, 14(4) :675-682.
  • 2BRINK J A, HEIKEN J P, BALFE D M, et al. Spiral CT: Decreased spatial resolution in vivo due to broadening of section-sensitivity profile [J]. Radiology,1992, 185(22):469-474.
  • 3WANG G, VANNIER M W. Helical CT image noise-analytical results[J]. Medical Physics, 1993, 20(6):1 635-1 640.
  • 4CRAWFORD C R, KING K F. Computed tomo graphy scanning with simultaneous patient translation[J]. Medical Physics, 1990, 17(6):967-982.
  • 5HSIEH J. Computed tomography: Principles, design, artifacts, and recent advances[M]. Bellingham, WA: SPIE Press, 2003:270-281.
  • 6HSIEH J. A general approach to the reconstruction of X-ray helical computed tomography[J]. Medical Physics, 1996, 23(2):221-229.
  • 7KALENDER W A, ARKDIUSZ P. Physical performance characteristics of spiral CT scanning [J]. Medical Physics, 1991, 18(5) :910-915.
  • 8WANG G, VANNIER M W. Low-contrast resolution in volumetric X-ray CT-analytical comparison between conventional and spiral CT [J]. Medical Physics, 1997, 24(3):373-376.