期刊文献+

微透析探针的重复利用性及自制线性探针的可行性研究 被引量:5

Capability of Reutilization of Microdialysis Probe and Feasibility of Establishment of Self-made Line Probe
下载PDF
导出
摘要 【目的】探讨微透析探针的可重复利用性以及线性探针的自制方法。【方法】采用SD大鼠进行体内试验,研究商品探针在体内试验前后效能的变化;利用F5型肾透析器中的纤维作为自制线性探针的透析膜,用体外测定回收率的方法探索其可行性。探针的体内外回收率的测定均采用反透析法。【结果】在经过长时间的体内试验之后,探针的效能只发生了3%的变化;自制探针的回收率虽然比商品探针低,但仍在可接受范围内,且效能稳定。【结论】商品探针可以重复使用;自制线性探针可以代替商品探针进行一些微透析研究。 Objective To study the capability of reutilization of microdialysis probe, and to find a feasible self- made method of establishing microdialysis probe ( line probe), so as to reduce the outlay of microdialysis research. Methods In-vivo efficiency of commercial probe was observed in rats before and after treatment. With the fiber from the Hemoflow F-Series Low-Flux Fresenius Polysulfone Capillary Dialysers as the dialysis membranes of the self-made line probe, the feasibility of this method was evaluated by determining the in-vitro probe recovery. Both of in-vivo probe recovery and in-vitro probe recovery were determined by retrodialysis. Results The results of long-term in-vivo test showed that only 3% of efficiency of the commercial probe was changed. Although the recovery of the self-made line probe was lower than that of the commercial probe, but the recovery was acceptable, and the efficiency of the probe was steady. Conclusion Commercial probe can be used repeatedly, and self-made line probe can be used as the replacement of commercial probe in some research of microdialysis.
出处 《广州中医药大学学报》 CAS 2008年第3期263-265,270,共4页 Journal of Guangzhou University of Traditional Chinese Medicine
基金 国家自然科学研究基金项目(编号:30772791 30672669) 广东省自然科学基金项目(编号:5300063)
关键词 青藤碱/分析 微透析探针/仪器与设备 色谱法 高压液相 SINOMENINE/analysis MICRODIALYSIS PROBE/instrumentation CHROMATOGRAPHY, HIGH PRESSURE LIQUID
  • 相关文献

参考文献5

二级参考文献26

  • 1严方,丁黎,赵陆华.微透析技术在体内药物分析中的应用[J].药学进展,2004,28(9):409-412. 被引量:7
  • 2凌家俊,李锐,周莉玲.青藤碱微透析回收率测定方法的体外模拟实验[J].广州中医药大学学报,2005,22(1):56-59. 被引量:14
  • 3舒鸿钧 韩慧婉 等.鼠脑微透析液中游离氨基酸的高效液相色谱分析[J].化学通报网络版,1999,:9900-9900.
  • 4De Lange E C, De Boer B A, Breimer D D. Microdialysis for pharmacokinetic analysis of drug transport to the brain [J]. Adv Drug Del Rev, 1999, 36 (2/3): 211.
  • 5Malonne, I Davies. A review of microdialysis sampling for pharmacokinetic applications [ J ]. Analytica Chimica Acta, 1999,379: 227.
  • 6Ma H M,Chin Chem Lett,1999年,10卷,3期,243页
  • 7Zhang H,J Mass Spectrometry,1999年,34卷,4期,377页
  • 8舒鸿钧,化学通报.网络版,1999年
  • 9韩慧婉,一种生化活体取样探针 .中国专利 ,编号 96 2 0 976 1.6,1996年
  • 10Wang Y,Pharmacol Res,1993年,10卷,10期,1411页