摘要
评价库尔特STKS全自动血球分析仪测定血小板的性能。通过不精密度、不准确度、线性范围的实验观察,库尔特STKS全自动血球分析仪血小板测定的性能可以满足临床实验室的要求。
Evaluates the performance for COULTER STKS fully automatic haemacytometer analyzer to assay blood platelet. The performance for the analyzer to assay blood platelet may meet the requirement of the clinical laboratory by the observation of non-precision non-accuracy, linear scope experiment.
出处
《中国医疗设备》
2008年第4期47-49,共3页
China Medical Devices
关键词
检验设备
血球分析仪
血小板计数
laboratory equipment
haemacytometer