本文采用流动注射在线萃取火焰原子吸收光谱法测定硫酸镍电解液中微量铅。考察了水相介质,共存离子、萃取装置、相比等因素的影响。分析含铅1.4mg/L和0.16mg/L的试样,分析值的相对标准偏差(n=10)分别为3.9%和12.3%,方法检出限为0.024mg/L。
An on line extraction flow injection method was developed for the determination of trace lead in nickel sulfate electrolyte using flame atomic absorption spectrometer as the detector.The influence of aqueous medium,coexisted ions,extraction device as well as phase ratio has been investigated.The relative standard deviations( n =10) for samples with lead concentration of 1.4mg/L and 0.16mg/L are 3.9% and 12.3% respectively.The detection limit of the method is 0.024mg/L.