铁(Ⅲ)-高碘酸钾-过氧化氢-变色酸2R催化动力学光度法测定痕量铁的研究 被引量:17

Iron(Ⅲ) Potassium periodate hydrogen peroxide Chromotrope 2R of Catalytic Kinetic Spectrophotometry to Determie Trace Iron(Ⅲ)
下载PDF
导出
摘要 研究了测定铁的一种新指示反应,在稀硫酸介质中,痕量铁(Ⅲ)对高碘酸钾与过氧化氢协同氧化变色酸2R的褪色反应具有强烈催化作用,其反应的动力学条件,表观活化能E′=189.81kJ/mol,表观反应速率常数K=5.67×10-4/s,半衰期t1/2=20.37min。反应温度为90℃,试验表明lgA0/A与Fe(Ⅲ)的浓度在30~100ng/25mL范围内符合Ber定律,建立了催化动力学光度法测定痕量铁的新方法。方法的检测限为1.25×10-9g/L,加入回收率在97.0%~102%,应用于测定西洋参口服液、美国花旗参茶和天然矿泉水中铁的含量结果满意。 In this paper,a new indicator reaction of potassium periodate and hydrogen peroxide with Chromotrope 2R in the presence of Fe(Ⅲ) as catalyst and the kinetic conditions have been studied.A new catalytic spectrophotometric method for determining trace Fe(Ⅲ) is established ,The limit of detection is 1.25×10 -9 g/L Fe,and the determination range is 30~100ng/25mL Fe.The method has been used for the analysis of A merican Ginseng,A merican Gingsen Tea and mineral water samples with satisfactory results.
机构地区 武汉大学化学系
出处 《分析试验室》 CAS CSCD 1997年第5期46-48,共3页 Chinese Journal of Analysis Laboratory
关键词 催化动力学 光度法 高碘酸钾 过氧化氢 Catalytic kinetic spectrophotometry potassium periodate hydrogen peroxide chromotrope 2R lron(Ⅲ)