期刊文献+

经关节螺钉固定术在下颈椎骨折脱位中的应用 被引量:3

Transarticular Screws for Treatment of Fracture and Dislocation of Lower Cervical Spine
下载PDF
导出
摘要 目的 探讨及评价经关节突螺钉技术治疗下颈椎脱位的应用效果。方法 使用经关节突螺钉技术治疗下颈椎骨折脱位17例,其中单节段固定12例,双节段5例。改良Klekamp经关节螺钉固定技术,以上位节段侧块背面中心点偏内侧1mm、偏下方1mm为入钉点,外倾20~25°,下倾35~40°行四层皮质固定。结果所有患者均获得随访,患者颈椎基本达到完全复位,无椎动脉及颈髓损伤等并发症,均达到了骨性愈合。结论 下颈椎经关节突螺钉置入简单,安全性高,生物力学固定融合性能好,适应范围广泛,是传统后路固定融合方法的创新与补充。 Objective To evaluate the effect of transarticular screws in treatment of fracture and dislocation of lower cervical spine. Methods From March 2006 to June 2007, 17 patients with cervical fracture and dislocation were treated with posterior transarticular screws. The single segment was fixed in 12 patients and 2 segments were fixed in 5. The technique of modified Klekamp transarticular screws was used. The entry point of screws insertion was located 1 mm inside and 1 mm under to the midpoint of lateral mass. With insertion angle of 20-25°protrudently and 35-40° downwards, 4 layer cortex were fixed. Results No serious complications occurred. All the fracture got fusion. Conclusion The technique of transarticular screws for treatment of fracture and dislocation of the lower cervical spine is useful and safe, and it can be widely used.
出处 《中国骨与关节损伤杂志》 2008年第6期447-449,共3页 Chinese Journal of Bone and Joint Injury
关键词 经关节螺钉 颈椎 关节突交锁 脱位 内固定 Transarticular screws Cervical spine Locked facet Dislocation Internal fixation
  • 相关文献

参考文献3

  • 1杨建东,王静成,冯新民,蒋百川,贾连顺,陶玉平,胡翰生.经C_(1、2)关节突螺钉治疗寰枢椎创伤和不稳的疗效及手术策略[J].中国骨与关节损伤杂志,2007,22(6):444-446. 被引量:10
  • 2Klekamp JW, Ugbo JL, Heller JG, et al. Cervical tranfacet versus lateral mass screws: a biomechinacial comparision. J Spinal Disord, 2000, 13:515
  • 3Xu R, Ebraheim NA, Nadaud MC, et al. The location of the cervical nerve roots on the posterior aspeec of the cervical spine. Spine, 1995, 20:2267

二级参考文献9

共引文献9

同被引文献47

  • 1燕树义,高晓荣,李学民,朱瑜琪,许多良.应用颈椎椎弓根螺钉内固定治疗颈椎骨折脱位[J].颈腰痛杂志,2005,26(6):433-436. 被引量:7
  • 2杨建东,王静成,冯新民,蒋百川,贾连顺,陶玉平,胡翰生.经C_(1、2)关节突螺钉治疗寰枢椎创伤和不稳的疗效及手术策略[J].中国骨与关节损伤杂志,2007,22(6):444-446. 被引量:10
  • 3Barnes AH,Eguizabal JA,Acosta FL Jr,et al.Biomechanical pullout strength and stability of the cervical artificial pedicle screw.Spine(Phila Pa 1976).2009;34(1):E16-20.
  • 4Bozkus H,Ames CP,Chamberlain RH,et al.Biomechanical analysis of rigid stabilization techniques for three-column Injury in the lower cervical spine.Spine (Phila Pa 1976).2005;30(8):915-922.
  • 5Yoshimoto H,Sato S,Hyakumachi T,et al.Spinal reconstruction using a cervical pedicle screw system.Clin Orthop Relat Res.2005;(431):111-119.
  • 6Ralston ME.Physiologic anterior subluxation:case report of occurrence at C5 to C6 and C6 to C7 spinal levels.Ann Emerg Med.2004;44(5):472-475.
  • 7Aderibigbe A,Ologe FE.Cervical spinal tuberculosis with tuberculous otitis media masquerading as otitis externa malignans in an elderly diabetic patient:case report.East Afr Med J.2004;81 (5):267-270.
  • 8Stitzel CJ,Morningstar MW,Paone PR.The effects of bite line deviation on lateral cervical radiographs when upper cervical Joint dysfunction exists:a pilot study.J Manipulative Physiol Ther.2003;26(7):E17.
  • 9Abe T,Kearns CF,Fukunaga T.Sex differences in whole body skeletal muscle mass measured by magnetic resonance imaging and its distribution in young Japanese adults.Br J Sports Med.2003;37(5):436-440.
  • 10Coskun O,Ucler S,Karakurum B,et al.Magnetic resonance imaging of patients with cervicogenic headache.Cephalalgia.2003;23(8):842-845.

引证文献3