摘要 采用ZLJ-C系列科里奥利质量流量计进行流体粘度检测的技术与方法;将流体及传感器敏感管(以下简称传感器管)置于柱坐标下对流体动力粘度和科里奥利质量流量计振动时的参数进行了系统分析;提出了一种新的粘度检测方法;利用量纲分析法对相关结论进行了验证。实际实验数据表明该方法是可行的。该技术简单、有效,可在不改变科里奥利质量流量计原有结构的条件下实施。 This article focuses on the topics of the viscosity measurement of the fluid passing the Coriolis mass flowmeter. The paper put the tube and the fluid into the cylindrical coordinates to analyse systematically. According to the study of relation of vibration parameter and dynamic viscosity, a new method was proposed firstly. After using dimensional analysis dealt with the problem, the result was tally with the theory which put forward. The paper translated the equation to a linear equation showed. And the correctness of the theory was proved by the experiments. The modification for the execution carried in the real Coriolis mass flow meter was small, even not necessary. And the operation of viscosity measurement was easy,appropriate and accurate in practice.
出处 《传感技术学报》 CAS CSCD 北大核心 2008年第5期891-895,共5页 Chinese Journal of Sensors and Actuators
关键词 科里奥利质量流量计 粘度 量纲分析 振动 Coriolis mass flowmeter viscosity dimensional analysis vibration
  • 相关文献

参考文献5

  • 1Paul Kalotay. Density and Viscosity Monitoring Systems Using Coriolis Flow Meters [J]. ISA Transactions, 1999, 38:303-310.
  • 2恩德斯+豪斯流量技术股份有限公司.粘度测量仪器:中国专利,02816604.3[P].2004.11.17
  • 3Wolfgang Drahm, Hege Bjonnes, et al. A Coriolis Meter with Direct Viscosity Measurement[J] : IEE Computing and Control Engineering 2003 : 14 : 42-43.
  • 4National Metal and Refining Company, Ltd. , Edison, N. J. In-line Vibratory Viscometer-Densitometer. United Stats Patent, 4, 524, 610[P]. Jun. 25. 1985.
  • 5西安东风机电有限公司.ZIJB1D型质量流量变送器使用说明书[S].西安:2003.11

同被引文献24

引证文献5

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部