针对直流耐压试验方法的局限性,介绍应用超低频耐压试验、串联谐振及变频谐振方式来进行交联聚乙烯电缆交流耐压试验,结合现场试验的经验介绍其试验原理和电气参数的计算方法。
An AC voltage withstand test on XPLE cable was carried out by method in order to improve the limitation of DC voltage withstand test. The of the test combined with the field experiments were introduced. using series resonance principle and calculation
出处
《绝缘材料》
CAS
2008年第3期63-65,共3页
Insulating Materials
关键词
交联聚乙烯电缆
串联谐振
交流耐压
cross-linked polyethylene(XPLE) cable
series resonance
AC voltage withstand