期刊文献+

碳纳米管/TiO2薄膜固定酶的生物传感器及电催化氧化H2O2的研究 被引量:1

Electrochemical oxidation of hydrogen peroxide at a HRP biosensor modified with TiO_2-decorated carbon nanotubes
下载PDF
导出
摘要 采用酸性溶胶法在碳纳米管上负载纳米TiO2颗粒,并制备了CNT-TiO2薄膜固定辣根过氧化物酶的生物传感器。研究了该生物传感器在磷酸盐缓冲溶液中对H2O2的电催化氧化作用及实验条件的影响。结果表明该生物传感器对H2O2表现出良好的电催化性能,在最佳实验条件下,对H2O2检测的线性范围为:4.2×10-7mol/L^3.2×10-3mol/L。检出限为:7.22×10-8mol/L。 The acid sol method was used for decorating TiO2 nanoparticles onto carbon nanotube surface. A gold elec- trode modified with TiO2-CNT was prepared. An amperometric horseradish peroxidase biosensor was prepared by immobilization of HRP in TiO2-CNT thin film on the gold electrode. The electrochemical oxidation of hydrogen peroxide was studied on this biosensor. The experiments showed that the nanoparticles could enhance the catalytic activity of immobilized enzyme. The linear detection range was 4.2 × 10^-7 mol/L - 3.2 × 10^-3 mol/L and the detection limit was 7.22 × 10^-8 mol/L.
出处 《分析试验室》 CAS CSCD 北大核心 2008年第6期5-8,共4页 Chinese Journal of Analysis Laboratory
基金 国家自然壳学基金(29975024,20275034)项目资助
关键词 生物传感器 CNT-TiO2 辣根过氧化物酶 化学修饰电极 Biosensor TiO2-CNT Horseradish peroxidase Chemically modified electrodes
  • 相关文献

参考文献10

  • 1Emmanuel T, Durrent J R. Anal Chem, 1998, 70:5 111
  • 2Emmanuel T, Anthony E G C. J Electroanal Chem, 2001, 517:20
  • 3Ang L M, Hor T S, Xu G O. Carbon, 2000, 38(3) : 363
  • 4Che G L, Lakshmi B B, Fisher E R. Nature, 1998, 48 (4) : 393
  • 5Yu R Q, Chen L W, Liu Q P. J Chem Mater, 1998, 10: 718
  • 6Jitianu A, Cacciaguerra T, Benoit R. Carbon, 2004, 42(5 - 6) : 1147
  • 7Li Q W, Zhang J, Yan H. Carbon, 2004, 42:287
  • 8Sung H L, Smithi P, Brij M. Colloids and Surfaces B, 2005, 40:93
  • 9Wendong W, Philippe S, Philippe K. Applied Catalysis B, 2005, 56:305
  • 10Li J, Tan S N, Ge H. Anal Chim Acta, 1996, 335:137

同被引文献27

  • 1颜权平,赵发琼,曾百肇.肾上腺素在碳纳米管-离子液体糊修饰电极上的伏安行为[J].分析科学学报,2006,22(5):523-526. 被引量:7
  • 2尹峰,赵紫霞,吴宝艳,王新胜,王艳艳,陈强.基于多壁碳纳米管和聚丙烯胺层层自组装的葡萄糖生物传感器[J].分析化学,2007,35(7):1021-1024. 被引量:23
  • 3Byung - Seon Kong , Dae - Hwan Jung , Sang- Keun Oh , et al Single-Walled Carbon Nanotube Gold Nanohybrids: Applica tion in Highly Effective Transparent and Conductive Films[J]. J Phys Chem C, 2007,111 (23):8377-8382.
  • 4Kenneth I. Ozoemena, Dudu Nkosi, Jeseelan Pillay. Influence of solution pH on the electron transport of the self-assembled nanoarrays of single-walled carbon nanotube-cobalt tetra-aminophthalocyanine on gold electrodes: Electrocatalytic detection of epinephrine[J]. Electrochimica Acta, 2008, 53 (6) : 2844- 2851.
  • 5Wang Cong, Wang Guangfeng, Fang Bin. Electrocatalytic oxida tion of bilirubin at ferrocenecarboxamide modified MWNTsgold nano-composite electrodes[J]. Microchim Acta, 2008.
  • 6Xiang Cuili,Ongjin Zouai-Xian Sun, et al. Direct electrochemistry and electrocatalysis of cytochrome c immobilized on gold nanopartieles-ehitosan-carbon nanotubes-modified electrode [J]. Talanta, 2007,74 (2) : 206-211.
  • 7Xu Jing, Wei Xian Wen,Song Xiao Jie, et al. Synthesis and electrocatalytic activity of multi-walled carbon nanotubes/Cu-Ag nanocomposites[J]. J Mater Sci, 2007,42(16):6972-6976.
  • 8Li Li Hua, Zhang Wei De. Preparation of carbon nanotubes supported platinum nanoparticles by an organic colloidal process for nonenzymatic glucose sensing[J]. Microchim Acta, 2008, 163(3-4) :305-311.
  • 9Zhang Wei , Yang Tao , Huang Darning , et al . Synergistic effects of nano-ZnO/multi-walled carbon nanotubes/ch3tosan nanocomposite membrane for the sensitive detection of sequencwspecific of PAT gene and PCR amplification of NOS gene. Journal of Membrane Science, 2008,325(1) : 245-251.
  • 10Chiu Jing-Yang, Yu Chung-Mu, Yen Miao-Ju, et al. Glucose sensing electrodes based on a poly (3, 4-ethylenedioxythio phene)/Prussian blue bilayer and multi-walled carbon nanotubes Biosensors and Bioelectronics[J]. Biosensors and Bioelectronics. In Press, Corrected Proof, Available online 31 October 2008.