FAIMS离子检测用高场非对称波电源设计 被引量:7

Design for High-field Asymmetric Waveform Power Supply with FAIMS
下载PDF
导出
摘要 介绍一种用于FAIMS(高场非对称波形离子迁移谱技术)离子检测器的电源,并简要说明FAIMS工作原理。针对FAIMS离子检测器的特点,设计了高场非对称波电源。实验结果表明,设计思路正确,电源达到了预定要求。 A kind of power supply used in FAIMS ( High-field Asymmetric Waveform Ion Mobility Spectrometry) and the theory of FAIMS have been introduced. According to the characters of FAIMS, a High-field Asymmetric Waveform power supply has been developed. The experimental result has been shown that the design of this power supply is correct.
出处 《科学技术与工程》 2008年第13期3470-3473,共4页 Science Technology and Engineering
基金 国家自然科学基金项目(60706030)资助
关键词 FAIMS 高场 非对称波 FAIMS High-field Asymmetric Waveform
  • 相关文献

参考文献4

  • 1[1]McDaniel E W,Mason E A.The mobility and diffusion of ions in gases.John Wiley & sons,1973
  • 2[2]Miller R A,Eiceman G A,Nazarov E G,et al.A MEMS radio-frequency lon mobility spectrometer for chemical agent detection.Sensors and Actuators A,2001;91:307-318
  • 3[3]Krylov E V.Pulses of special shapes formed on a capacitive load.Instruments and Expermental Techniques,1997;40(5):628-631
  • 4[4]Miller R A,Eiceman G A,Nazarov E G,et al.A MEMS radio-frequency lon mobility spectrometer for chemical agent detection.Sensors and Actuators A,2001;91:307-318

同被引文献62

  • 1纪军,张彦,王梨平,黄启斌.新型不对称场离子迁移谱检测技术及其应用[J].现代科学仪器,2005,22(3):9-12. 被引量:12
  • 2张东风,孔德义,梅涛,陶永春.离子迁移谱仪微型化的现状与进展[J].仪器仪表学报,2006,27(2):199-204. 被引量:22
  • 3李刚,陈强,赵建龙.离子迁移谱技术及其在生命分析化学中应用[J].现代仪器,2006,12(2):31-34. 被引量:4
  • 4时迎国,劭士勇,李安林,姚琏,王宾,李芳,王俊德,李海洋.迁移管的电场强度对真空紫外电离-离子迁移谱仪性能的影响[J].分析化学,2006,34(9):1353-1356. 被引量:13
  • 5Earl Wadsworth McDaniel, Edward A Mason. The mobility and diffusion of ions in gases[M]. New York, USA: Willey, 1973.
  • 6Shvartsburg Alexandre A, Keqi Tang, Smith Richard D. Optimization of the design and operation of FAIMS analyzers[J]. J Am Soc Mass Spectrom, 2005, 16(1): 2-12.
  • 7Eiceman G A, Nazarov E G, Miller R A. A micro-machined ion mobility spectrometer-mass spectrometer[J]. IJIMS, 2000, 3 (1):15-27.
  • 8Raanan A Miller, Gary A E;iceman, Erkinjon G Nazarov. A micromaehined field asymmetric ion mobility spectrometer (FAIMS)[J]. IJIMS, 2002, 5(2): 118-134.
  • 9Krebs M D, Zapata A M, Nazarov E G, et al. Detection of biological and chemical agents using differential mobility spectrometry (DMS) technology[J]. Sensors Journal, 2005, 5 (4): 696- 703.
  • 10Borsdorf H, Nazarov E G, Miller R A. Time of-flight ion mob ility spectrometry and differential mobility spectrometry: A comparative study of their efficiency in the analysis of halogenated compounds[J]. Talanta, 2007, 71(4): 1804-1812.

引证文献7

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部