期刊文献+

内电解技术对高浓度化工废水的预处理 被引量:9

PRETREATMENT TECHNOLOGY OF CHEMICAL WASTEWATER WITH HIGH CONCENTRATION BY Fe/C INNER-ELECTROLYSIS METHOD
下载PDF
导出
摘要 通过无曝气内电解技术预处理高浓度工业废水,在pH4~5、固液比0.8g/mL、停留时间60min、铁炭质量比3∶1时的最佳条件下,COD及色度的去除率分别为71.6%和87.5%,BOD5/COD值从0.09提高到0.19,达到了较好的预处理效果。同时,研究了反应温度对内电解反应的影响。 A study on pretreatment of chemical industry wastewater with high concentration contamination by non-aeratd inner-electrolysis was carried out.The optimum operation conditions are as follows:pH is 4~5,the rate of the solid quality and the liquid bulk is 0.8 g/mL,HRT is 60 min,The ratio of the iron and the active carbon quality is 3∶1,the removal rates of COD and chromaticity were 71.6% and 87.5% respectively,the BOD5/COD ratio was improved from 0.09 to 0.19,and the method reached a good pretreatment effect.And the effect of the reaction temperature on the inner-electrolysis was studied,too.
出处 《环境工程》 CAS CSCD 北大核心 2008年第3期45-47,共3页 Environmental Engineering
基金 甘肃省科技攻关项目(GS022-A52-082) 兰州大学功能有机分子化学国家重点实验室开放基金(NKLAOC2004-39) 兰州大学交叉学科青年创新研究基金(LZU200505)资助
关键词 内电解 工业废水 COD 色度 inner-electrolysis industrial wastewater COD chromaticity