摘要
建立了液相色谱-氢化物发生-原子荧光联用同时检测预混料中阿散酸和洛克沙胂的实验方法。饲料样品采用20%甲醇水溶液为提取液,用超声、振荡提取方法,用symmetry shield TM RP18柱150mm×4.6mm,5μm分离,以含0.1%甲酸的0.05mol/L磷酸二氢钾溶液:甲醇(95:5)为流动相,流速为1.0mL/min,进样量100μm条件下,于193.7nm波长处检测。实验条件下:阿散酸、洛克沙胂的浓度在0.2—4μg/mL范围内,含量与峰面积呈良好的线性关系,R^2分别为0.9992,0.9990。三个添加水平上方法回收率为96.40%-107.42%,RSD 0.86%-5.20%。
Development of simultaneous analysis of p-arsenilic and roxarsone in animal feed hy liquid chromatography-hydrodide-atomic-flurescence spectrometry,adopting 20% (ratio of volume) methylalcolhol aqueous solution as extracts to pretreatment samples, ultrasound bath, shaked, then through C18 chromatography pillar separates, using 0.05 mol/L K2HPO4:CH3OH(95:5 )as mobile phase, at a rate of 1 mL/min,inject 100μL,detected at 193.7 nm,the result showed that:the Linear range was 0.2 -4μg/mL, with linear relative coefficient,p-arsenilic acid R^2 is 0.999 2, roxarsone R^2 is 0. 999 0, the average recoveries of three different addition level were 96.40% - 107.42%, RSD was 0.86% - 5.20%.
出处
《应用化工》
CAS
CSCD
2008年第6期694-696,710,共4页
Applied Chemical Industry
关键词
阿散酸
洛克沙胂
饲料
液相色谱-氢化物发生-原子荧光
同时检测
p-arsenilic acid
roxarsone
feed
Liquid chromatography-hydrodide-atomic-flurescence spec- trometry
simultaneous analysis