期刊文献+

基于瞬时无功功率理论的SVC设计和实现 被引量:5

Design and Realization of SVC based on the Instantaneous Reactive Power Theory
下载PDF
导出
摘要 为了提高静止无功补偿装置(SVC)的响应速度,根据对称分量法和瞬时无功功率理论推导出了基于瞬时有功、无功电流的SVC补偿导纳实用算法,并设计出了35kV的SVC实际装置,在MATLAB仿真中对SVC的补偿效果进行了比较分析;最后给出了实际装置的运行效果。仿真和实际运行表明,基于该算法的SVC装置具有响应速度快,补偿效果好的特点。 In order to improve response speed of Static Var Compensator (SVC),according to method of synchronous symmetrical component and instantaneous reactive power theory,the utility compensator admittance based on instantaneous active and reactive current was deduced,and a 35 kV SVC was designed.The analysis and comparison between the effects of compensation was implemented in Matlab software,and the running results of actual device were given.Simulation and actual operation verify the SVC based on the method has feature of rapid response speed and perfect result of compensation .
出处 《电力电子技术》 CSCD 北大核心 2008年第5期12-13,47,共3页 Power Electronics
关键词 供电系统 补偿器 无功功率补偿 power supply compensator reactive power compensation
  • 相关文献

参考文献2

  • 1Timothy J E Miller.Reactive Power Control in Electric Systems[M].New York:A Wiley-Interscience Publication,1982.
  • 2王兆安 杨君 刘进军.谐波抑制和无功补偿[M].北京:机械工业出版社,2002..

共引文献2

同被引文献24

引证文献5

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部