电厂锅炉EDTA清洗废水回收处理 被引量:4

Recycle and treatment of EDTA cleaning wastewater from boiler in power plant
下载PDF
导出
摘要 采用化学预处理-膜法处理电厂锅炉EDTA清洗废水。首先加入NaOH溶液,将废水pH调至13以上,以去除金属离子;然后用硫酸将滤液pH调至0.5以下,以析出EDTA;再用纳滤和反渗透系统净化滤液,以使出水达到排放要求。试验结果表明,当废水经碱酸法化学预处理、纳滤系统净化、再经反渗透处理后出水CODCr可达到100 mg/L,能直接排放。 Boiler EDTA cleaning wastewater from power plant was treated by membrane combining with chemical pretreatment. NaOH solution was first added to ensure that the wastewater pH was more than 13 to remove metal ion, sulphuric acid was then added to ensure that the filtrate pH was less than 0.5 to precipitate EDTA, finally supernatant fluid was treated by nanofiltration and osmosis sys- tem to ensure that the effluent could be drained directly. It was resulted that when wastewater by chemical alkali acid pretreatment, nanofiltration purification system, the reverse osmosis water treatment CODcr concentration was below 100 mg/L , can be letted directly .
出处 《清洗世界》 CAS 2008年第5期1-3,9,共4页 Cleaning World
关键词 EDTA清洗 废水 纳滤 反渗透 化学预处理 EDTA cleaning wastewater nanofiltration osmosis chemical pretreatment
  • 相关文献

参考文献6

二级参考文献21

  • 1李永旺.锅炉化学清洗废液的处理[J].山东电力技术,1994,0(2):16-20. 被引量:1
  • 2李永旺.EDTA清洗废液的回收[J].华北电力技术,1996(2):52-55. 被引量:5
  • 3葛素莉,肖明,张福章.300MW机组热力系统利用EDTA钠盐进行清洗[J].河北电力技术,1996,15(3):36-38. 被引量:3
  • 4卓山.EDTA化学清洗综述[J].浙江电力,1996,15(6):30-32. 被引量:4
  • 5张柏林.协调EDTA洗炉新法的研究[J].中国腐蚀与防护学报,1985,5(4).
  • 6[15]Brad Buecker, Ellis Loper. Proper circulation critical to effective boiler cleaning[J].Power Engineering, 2001,105(5):51 ~ 52.
  • 7[16]Brad Buecker,Wofford John. Chemical cleaning clears San
  • 8[17]Miguel's boiler tubes[J].Power Engineering, 1994,98(6):36~ 37.
  • 9[22]C.P Huang,Mei-Chih Hsu,Paul Miller,Recovery of EDTA from plant boiler chemical cleaning waste [J],Journal of Environmental Engineering ,2002,126(10):919~924.
  • 10[1]Huchler A Loraine. HP in Water Management[J]. HydrocarbonProcessing, 2000(7): 99.

共引文献42

同被引文献39

引证文献4

二级引证文献24

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部