期刊文献+

屏蔽电极可行性的理论分析与实验研究

Theoretical Analysis and Experimental Research for the Feasibility of Shield Electrode
下载PDF
导出
摘要 在使用传统四电极电导传感器对油井产出液的含水率进行实际测量时,由于传感器两端电位近似为零而造成激励电流漏失,导致含水率测量精度下降。提出在原有四电极基础上增加两个屏蔽电极的改进方案,建立了含屏蔽电极电导传感器内电流密度分布的理论模型,并对屏蔽电极的宽度和间距进行了优化设计,理论上漏失程度可由原来的31.5%下降到0.36%。环状流型下的实验结果表明,屏蔽电极可有效减少漏失条件下激励电流的漏失,传感器测量精度有较大提高。大庆油田现场试验结果表明,传感器测量相对误差小于5%。 In order to decrease the exciting current leakage and improve the measuring precision ot water Iraction under oil-well logging application when using basic four-electrode conductance sensor, a new six-electrode conductance sensor characterized by adding two shield electrodes was proposed. A theoretical model of the current density distribution inside the new conductance sensor was instructed. The distance and width of the two shield electrodes were optimized ,and the leakage degree was reduced from 31.5% to 0.36% theoretically. The experiment was performed with reference to annular phase distributions in laboratory, and the results demonstrate that the two shield electrodes is feasibility and the measuring precision of water fraction is improved greatly. The trial result in Daqing oilfield shows that the measuring relative error of the new six-electrode probe is less than 5%.
出处 《化工自动化及仪表》 CAS 2008年第4期38-43,共6页 Control and Instruments in Chemical Industry
基金 国家"863"计划资助项目(2007AA06z231)
关键词 计量学 屏蔽电极 电导传感器 含水率测量 metrology shield electrode conductance sensor water fraction measurement
  • 相关文献

参考文献11

  • 1FOSSA M. Design and Performance of a Conductance Probe for Measuring the Liquid Fraction in Two-phase Gas-liquid Flows [ J ]. Flow Meas Instrum, 1998,9 : 103 - 109.
  • 2DEVIA F, FOSSA M. Design and Optimization of Impedance Probes for Void Fraction Measurements [ J ]. Flow Meas Instrum, 2003,14 : 139 - 149.
  • 3LUCAS G P, CORY J C, WATERFALL R C,et al. Measurement of the Solids Volume Fraction and Velocity Distributions in Solids-liquid Flows Using Dual-plane Electrical Resistance Tomography [ J ]. Flow Meas Instrum, 1999,10 : 249 - 258.
  • 4LUCAS G P, CORY J C, WATERFALL R C. A Six-electrode Local Probe for Measuring Solids Velocity and Volume Fraction Profiles in Solids-water Flows[ J]. Meas Sci Technol,2000,11 : 1498 - 1509.
  • 5JIN Ning-de , WANG Jun , XU Li-jun. Optimization of a Conductance Probe with Vertical Multi-electrode Array for the Measurement of Oil-water Two-phase Flow [ C ]//Proceedings of Second International Conference on Machine Learning and Cybernetics. Xi' an, China,2003 : 899 - 905.
  • 6金宁德,邢荣亮,赵鑫.纵向八电极阵列电导式两相流测量方法研究[J].测井技术,2005,29(6):484-487. 被引量:11
  • 7HU Jin-hai, LIU Xing-bin ,ZHANG Yu-hui, et al. The Application of Cross-correlation Technique Based on Conductance Sensor in Production Wells [ C ]//The 4th International Symposium on Measurement Techniques for Muhiphase Flows. Hangzhou, China,2004 : 573 - 578.
  • 8LIU Xing-bin, HU Jin-hai, HUANG Chun-hui, et al. Conduct ance Sensor for Measurement of the Fluid Watercut and Flow rate in Production Wells [ C ]//The 5th International Symposium on Measurement Techniques for Muhiphase Flows. Aomen China ,2006:440 - 443.
  • 9赵鑫,金宁德,陈万鹏,孙爱东.纵向多极阵列电导式两相流测量系统研究[J].仪器仪表学报,2006,27(10):1253-1257. 被引量:7
  • 10李英伟,孔令富,刘兴斌,胡金海.阻抗式含水率测量仪激励源的优化设计[J].化工自动化及仪表,2007,34(2):73-75. 被引量:11