期刊文献+

红外凝视成像光学微扫描重建技术研究 被引量:6

RESEARCH ON OPTICAL MICROSCANNING RECONSTRUCTION FOR INFRARED STARING IMAGING
下载PDF
导出
摘要 由于有限的焦平面阵列等因素影响,红外热成像系统的空间分辨率较低.理论上,微扫描能有效提高空间分辨率,然而光学系统不易精确控制,导致重建图像模糊.针对此问题,本文提出了基于帧间块匹配的图像配准算法.该算法有效地实现了亚像元成像,在提高空间分辨率的同时,抑制了图像模糊. The spatial resolution of infrared thermal imaging is low due to finite focal plane array(FPA) and so on. Theoretlcally, microscanning can improve resolution effectively, however, reconstruction of image is blurry due to imprecise optical system controlling. To solve this problem, a reconstruction algorithm based on frame matching was proposed in the study. This approach achieved sub-pixel imaging. Experimental results show that imaging spatial resolution is improved and image blur is restrained.
出处 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2008年第4期257-260,共4页 Journal of Infrared and Millimeter Waves
基金 国防预研基金(40405050303)资助项目
关键词 红外热成像 光学微扫描 图像重建 块匹配 infrared thermal imaging optical microscanning image reconstruction block matched
  • 相关文献

参考文献7

二级参考文献32

  • 1陈媛媛,余金中,陈少武,樊中朝.SOI波导弯曲损耗改善方法的研究[J].红外与毫米波学报,2005,24(1):53-55. 被引量:4
  • 2万尤宝,杨培志,吴宇容,袁国祥,李新曦,Rong-Min Kang.组分离子浓度对铁电铌酸钾锂晶体Raman光谱的影响[J].红外与毫米波学报,2005,24(5):331-334. 被引量:2
  • 3Sendall R L, Rosell R A. Static performance model based on the perfect synchronous integrator model [ R]. AD/A -073763. Appendix D, 1979.
  • 4Scott L B, Agostino J D. NVEOD FLIR92 thermal imaging systems performance model [ C ] , Proc. SPIE Aerospace Sensing Symposium, 1992, 1689( 13 ) : 194-203.
  • 5Stein C L,Karin W B.Characteristic of shipborne targets in warm coastal environments in mid-and long-wave IR [ J ].SPIE,1997,3219:52-64.
  • 6Ekstrand B.Approach to estimation of infrared point target range [J].Appl.Opt.,2000,39(20):3495-3503
  • 7Jean Fortin, Paul Chevere. Realization of a fast microscanning device for infrared focal plane arrays. In:Proc. SPIE, 1996,2742:185-196
  • 8Fred P Blommel, Dr Peter N J Dennis. The effect of microscan operation on starring infrared sensor imagery. In:Proc.SPIE.2000,1540:653-664
  • 9Edward A Watson, Robert A Muse, Fred P Blommel. Aliasing and blurring in microscanning imagery. In:Proc.1992, 1689:242-250
  • 10Kai M Hock. Effect of oversampling in pixel arrays.Optical Engineering,34(5):1281-1288