期刊文献+

围产儿氧饱和度监测方法及其临床评价 被引量:1

原文传递
导出
摘要 目前,新生儿窒息率及围产期死亡率仍较高。其原因与临床医生对氧饱和度监测缺乏足够重视有关。随着对婴儿健康重视程度的提高,有学者提出将血氧饱和度作为儿科第五生命体征进行常规监测。为降低新生儿窒息率及围产期死亡率,应率先发展氧饱和度监测技术。现就围产期氧饱和度监测方法及其效果作一综述。
出处 《中华围产医学杂志》 CAS 2008年第4期280-282,共3页 Chinese Journal of Perinatal Medicine
  • 相关文献

参考文献28

  • 1Bernet-Buettiker V, Ugarte MJ, Frey B, et al. Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients. Pediatrics, 2005, 115 : e64-e68.
  • 2陈克正.危重新生儿转运设备简介[J].小儿急救医学,2001,8(2):73-75. 被引量:1
  • 3James J, Tiwari L, Upadhyay P, et al. Evaluation of pulseoximetry oxygen saturation taken through skin protective covering. BMC Pediatr, 2006, 6:14.
  • 4Goldman JM, Petterson MT, Kopotic RJ, et al. Masimo signal extraction pulse oximetry. J Clin Monit Comput, 2000, 16:475-483.
  • 5Workie FA, Rais-Bahrami K, Short BL. Clinical use of new- generation pulse oximeters in the neonatal intensive care unit. Am J Perinatol, 2005, 22:357-360.
  • 6Sahni R, Gupta A, Ohir-kist K, et al. Motion resistant pulse oximetry in neonates. Arch Dis Child Fetal Neonatal Ed, 2003, 88:F505-F508.
  • 7Alshimmiri M, Boeking AD, Gagnon R, et al. Prediction of umbilical artery base excess by intrapartum fetal oxygen saturation monitoring. Am J Obstet Gynecol, 1997, 177:775-779.
  • 8Reddy VK, Holzman IR, Wedgnood JE. Pulse oximetry saturations in the first 6 hours of life in normal term infants. Clin Pediatr(phila), 1999,38:87-92.
  • 9孙迎军.脉搏氧饱和度监护仪在563例新生儿疾病中的应用[J].徐州医学院学报,2001,21(2):154-155. 被引量:4
  • 10Arlettaz R, Bauschatz AS, Monkhoff M, et al. The contribution of pulse oximetry to the early detection of congenital heart disease in newborns. Eur J Pediatr, 2006, 165:94-98.

二级参考文献84

共引文献189

同被引文献13

  • 1Kattwinkel J, Perlman JM, Aziz K, et al. Part 15: neonatal resuscitation: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care[J]. Circulation, 2010, 122(18 Suppl 3):$909-919.
  • 2Rabi Y, Yee W, Chen SY, et al. Oxygen saturation trends immediately after birth[J]. J Pediatr, 2006, 148(5):590-594.
  • 3Dawson JA, Davis PG, O'Donnell CP, et al. Pulse oximetry for monitoring infants in the delivery room: a review[J]. Arch Dis Child Fetal Neonatal Ed, 2007, 92(1):F4-7.
  • 4Harris AP, Sendak M J, Donham RT. Changes in arterial oxygen saturation immediately after birth in the human neonate[J]. J Pediatr, 1986, 109(1):117-119.
  • 5林振浪.呼吸系统解剖生理特点//邵肖梅,叶鸿冒,丘小汕.实用新生儿学[M】4版.北京:人民卫生出版社,2014:318-319.
  • 6Goldsmith JP, Kattwinkel J. The role of oxygen in the delivery room[J]. Clin Perinatol, 2012, 39(4):803-815.
  • 7Hartnett ME, Lane RH. Effects of oxygen on the development and severity of retinopathy of prematurity[J]. J AAPOS, 2013, 17(3):229 234.
  • 8Maxwell LG, Harris AP, Sendak MJ, et al. Monitoring the resuscitation of preterm infants in the delivery room using pulse oximetry[J]. Clin Pediatr (Phila), 1987, 26(1):18-20.
  • 9Dawson JA, Kamlin CO, Vento M, et al. Defining the reference range for oxygen saturation for infants after birth[J]. Pediatrics, 2010, 125(6):e1340-1347.
  • 10Baquero H, Alviz R, Castillo A, et al. Avoiding hyperoxemia during neonatal resuscitation: time to response of different SpO2 monitors[J]. Acta Paediatr, 2011, 100(4): 515- 518.

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部