一种准确简便地标定氧化锆氧量分析仪的新方法

A New Method for Calibrating of the Zirconia Oxygen Analyzer
下载PDF
导出
摘要 本文提出仅用一种标准气或不用标准气标定氧化锆氧量分析仪的新方法。它符合我国的相关检定规程,适宜含氧量下限不小于0.1%的氧量分析仪的首次检定、后续检定和使用中的检验,尤其适宜在发电厂使用了较长时间后,对"检测器的多孔陶瓷过滤网已破损或其气孔被堵塞程度不明"的情况下进行检定或标定。 This paper persents a new method of using only one standard gas or without using any standard gases to calibrate zirconia oxygen analyzers. This method conforms to the related verification regulation which is suitable to calibrate zirconia oxygen analyzers for the first or follow-up time and also suitable to calibrate the analyzers being used, on condition that oxygen content should be kept above the pre-determined minimum of 0.1%.This method is especially suitable for calibrating when the analyzers has been used for a long time in a power plant, even if the porous ceramic filter has been broken, or not knowing whether a lot of porous are blocked up.
作者 张涛 林金秋
出处 《自动化技术与应用》 2008年第8期24-26,53,共4页 Techniques of Automation and Applications
关键词 氧化锆氧分析仪 标定的方法 陶瓷过滤网的堵塞 zirconia oxygen analyzer calibrating method blocked porous
  • 相关文献

参考文献5

  • 1国家质量监督检验检疫总局:国家计量检定规程JJG535-2004氧化锆氧分析器检定规程[S].中国计量出版社,北京.2005
  • 2张涛..氧化锆氧量分析仪的标定[EB/OL]..www.ohina 5c.com,,2008-02-18..
  • 3DL/T774-04.中国电力行业标准:火力发电厂热工自动化系统检修运行维护规程[S].,.P42-44.
  • 4哈尔滨龙成智能仪表公司:JZY-Ⅱ型氧量自动检测仪的使用说明书http://paul2.gol.icpcn.com[EB/OL](2008-02-18)
  • 5国家质量技术监督局:中国国家计量技术规范JJF1059-1999《测量不确定度评定与表示》[S].(2000年)