在修编过程中对标准的适用性作了适当调整,提出了对少量特殊建筑的单独要求;增加了给排水和电气方面的节能内容,修改和增加了对暖通方面的节能规定,如需要计算净排风能量回收效率,对内区全空气系统和风机盘管系统冬季降温提出新要求等,并对上述内容作了分析和说明。
Presents some revision were made in the applicability of the standard, and puts forward special requirements for a few kinds of buildings. Adds some items for energy efficiency of water supply and drainage and electrical engineering, and modifies or adds energy saving regulations of HVAC systems, for example, the net heat recovery efficiency of exhaust air should be calculated, and puts forward the lowering temperature requirements of all-air systems and fan coil unit systems in inner zone of buildings in winter.
出处
《暖通空调》
北大核心
2008年第9期4-10,共7页
Heating Ventilating & Air Conditioning
关键词
最大新风比
热回收
建筑内区
冷却塔供冷
maximum fresh air .ratio, heat recovery, inner zone of building, cooling tower cooling