期刊文献+

碳纳米管顶空固相微萃取—气相色谱法测定土壤中有机氯农药 被引量:11

Determination of organochlorine pesticides in soil by headspace solid phase microextraction and GC
下载PDF
导出
摘要 采用碳纳米管顶空固相微萃取—气相色谱法测定了土壤中有机氯农药,探讨了萃取时间、萃取温度、搅拌速度、离子强度、有机溶剂和土壤加水量对萃取效率的影响。该方法的线性范围为0.5~50.0ng/g,r>0.9915,检出限为0.03~0.33ng/g。样品的加标回收率为91.4%~120.0%,相对标准偏差不大于12.7%。 A headspace solid phase microextraction (HSSPME) method was developed as the first step for determination of organochlorine pesticides in soil samples. Carbon nanotube on stainless steel wires were prepared for the microextraction procedure. The effects of extraction time, temperature, agitation, ionic strength, organic solvent and soil dilution on the extraction efficiency were determined. Employing the best extraction conditions (45 min ex- traction at 65 ℃, mild agitation, 0.25 g Na2SO4/1.0 g soil, no organic solvent, and 1-4 mL water/0.5 g soil), linear calibration equations were established for 8 pesticides (α-BHC, β-BHC, δ-BHC, γ-BHC, pp'-DDE, op'-DDT, pp'-DDD, pp'-DDT) in the range of 0.5-50.0 ng/g with correlation coefficients of 〉0. 991 5. The detection limits (LOD, S/N: 3) for the 8 pesticides ranged from 0.03-0.33 ng/g. Applying the method to contaminated soil samples, the recovery factors ranged from 91.4%- 120.0% for the 8 pesticides with a relative standard deviation of ≤12.7%.
出处 《环境污染与防治》 CAS CSCD 北大核心 2008年第9期65-69,共5页 Environmental Pollution & Control
关键词 碳纳米管 有机氯农药 顶空固相微萃取 土壤 气相色谱 carbon nanometer tube organochlorine pesticides headspace solid phase microextraction; soil GC
  • 相关文献

参考文献4

二级参考文献21

  • 1Abir Khaled,Janusz Pawliszyn.Journal of Chromatography A,2000,(892): 455
  • 2Carlo Bicchi,Stefania Drigo,Patrizia Rubiolo.Journal of Chromatography A,892(2000): 4692
  • 3Heather Lord,Janusz Pawliszyn.Journal of Chromatography A,2000,(885): 153
  • 4Ruey-An Doong,Pei-Lin Liao.Journal of Chromatography A,2001,(918): 177
  • 5Zoltan Mester,Janusz Pawliszyn.Journal of Chromatography A,2000,(873): 129
  • 6Namiesnik J, Zygmunt B, Jastrzebska A. Application of Solid-Phase Microextraction for Determination of Organic Vapors in Gaseous Matrices. J Chromatogr A, 2000, 885(1-2):405-418.
  • 7Koziel J A, Novak I. Sampling and Sample-Preparation Strategies Based on Solid-Phase Microextraction for Analysis of Indoor Air. Trends in Analytical Chemistry, 2002, 21(12):840-850.
  • 8Llompart M, Li K, Fingas M. Headspase Solid-Phase Microextraction for the Determination of Volatile and Semivolatile Pollutants in Water and Air. J Chromatogr A, 1998,824( 1 ) :53-61.
  • 9Elke K, Jermann E, Begerow J, et al. Determination of Benzene, Toluene, Ethylbenzene and Xylenes in Indoor Air at Environmental Levels Using Diffusive Samplers in Combination with Headspaee Solid-Phase Microextraetion and High Resolution Gas Chromatography-Flame Ionization Detection. J Chromatogr A, 1998, 826(2) : 191-200.
  • 10Martos P A, Pawliszyn J. Calibration of Solid-Phase Microextraction for Air Analyses Based on Physical Chemical Properties of the Coating. Anal Chem, 1997, 69(2) :206-215.

共引文献18

同被引文献1307

引证文献11

二级引证文献67

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部