期刊文献+

基于晋城市工业园区PM10容量核算方法的研究

Study on PM_(10) Capacity Evaluation for Jincheng Industrial Park
下载PDF
导出
摘要 在功能区划分的基础上,应用A-P值法对山西省晋城市工业园区的PM10容量进行核算.计算得出该地区的PM10总排放量和总削减量,以及各污染源的削减量.计算结果表明,该地区的PM10排放量超过国家标准,应立即采取补救措施. Based on the distribution of functional zones, PM10 environment capacity of Jincheng Industrial Park, Shanxi Province, was measured by using A - P value method. The outcome of the calculation involves the overall amount of PM10 emission and the total reduced amount in the area, together with the reduction amount of various pollution sources. The results suggest that the PM10 emission in this area exceedes national standard and measures should be taken immediately to address such a problem.
出处 《南京工程学院学报(自然科学版)》 2008年第2期57-61,共5页 Journal of Nanjing Institute of Technology(Natural Science Edition)
基金 南京工程学院大学生科技创新基金项目(NB2006146)
关键词 PM10 容量 A-P值法 多源模式法 PM10 environment capacity A -P value method multiple source modeling