摘要 目的探讨DWIBS周围神经成像扫描参数的优化方案。方法对5只健康新西兰白兔行坐骨神经冠状位MRN成像,评价不同参数组合DWIBS序列及T2WI/SPIR图像兔坐骨神经的显示效果以及图像信号噪声比(SNR)与对比噪声比(CNR)。制作兔坐骨神经组织切片。结果T2WI/SPIR图像和b值=200 s/mm^2、层厚=2 mm的DWIBS序列兔坐骨神经成像效果较好。T2WI/SPIR图像SNR和CNR最高。DWIBS中,以b值=200 s/mm^2、层厚=1.5 mm序列SNR、CNR最高。结论采用适当b值(200 s/mm^2)和薄层扫描(1.5 mm)能够获得较好的兔坐骨神经DWIBS图像。 Objective To discuss DWIBS imaging protocols of peripheral nerve imaging. Methods MRN imaging of each sciatic nerve were obtained coronally in 5 adult New Zealand white rabbits. All images of rabbit sciatic nerve in DWIBS and T2WI/SPIR were observed, and the imaging qualities were evaluated by measurement the signal intensity of middle segment of sciatic nerve (SN), muscle (SM) and background (SD), also calculating signal-noise ratio (SNR) and contrast-noise ratio (CNR) of each sequence. Results The rabbit sciatic nerve was showed with high signal, especially on DWIBS (with b value =200 s/mm^2, slice thickness= 2 mm) and T2WI/SPIR. Among all images, T2WI/SPIR got the highest SNR and CNR. SNR and CNR of DWIBS with b value= 200 s/mm^2 , slice thickness = 2 mm was higher than those of other DWIBS sequences. Conclusion Preferable rabbit sciatic nerve DWIBS could be obtained with higher SNR and CNR by adopting b value (200 s/mm^2) and smaller slice thickness. Histopathologic factors impacted DWIBS neuroimaging.
出处 《中国医学影像技术》 CSCD 北大核心 2008年第10期1530-1533,共4页 Chinese Journal of Medical Imaging Technology
关键词 坐骨神经 磁共振成像 扩散加权成像 Sciatic nerve Magnetic resonance imaging Diffusion-weighted imaging
  • 相关文献

参考文献12

  • 1Aagaard BD, Maravilia KR, Kliot M. Magnetic resonance neurography: magnetic resonance imaging of peripheral nerves. Neuroimaging Clin N Am, 2001,11(1):131- 146.
  • 2Cudlip SA, Howe FA, Griffiths JR, et al. Magnetic resonance neurography of peripheral nerve following experimental crush injury, and correlation with functional deficit. J Neurosurg, 2002, 96 (4) :755-759.
  • 3Takahara T, Imai Y, Yamashita T, et al. Diffusion weighted whole body imaging with background body signal suppression (DWIBS) : technical improvement using free breathing, STIR and high resolution 3D display. Radiation Medicine, 2004,22(4):275- 282.
  • 4Takahara T, Imai Y, Yamashita T, et aI. Feasibility of high resolution diffusion-weighted MR neurography for spinal nerves. Mag Reson Med, 2004:11.
  • 5Maravilla KR, Bowen BC. Imaging of the peripheral nervous system: evaluation of peripheral neuropathy and plexopathy. AJNR Am J Neuroradiol, 1998,19(6) :1011-1023.
  • 6Ross JS. Newer sequences for spinal MR imaging: smorgasbord or succotash of acronyms? AJNR Am J Neuroradiol, 1999, 20 (3): 361-373.
  • 7Chrysikopoulos H, Pappas J, Papanikolaou N, et al. Bone marrow lesions: evaluation with fat-suppression turbo spin echo MR imaging at 0.5T. Eur Radiol, 1996,6(5) :895-899.
  • 8Niitsu M, .Tohno E, Itai Y. Fat suppression strategies in enhanced MR imaging of the breast: comparison of SPIR and water excitation sequences. J Magn Reson Imaging, 2003,18(3) :310 -314.
  • 9李新春,陈健宇,刘庆余,沈君,梁碧玲.正常臂丛节后神经MR神经成像术[J].中国医学影像技术,2004,20(1):105-107. 被引量:36
  • 10Clark CA, Hedehus M, Mosely ME. In vivo mapping of the fast and slow diffusion tensors in human brain. Magn Reson Med, 2002,47(4) : 623-628.

二级参考文献6

  • 1[1]Posniak HV, Olson MC, Dudiak CM, et al. MR imaging of brachial plexus[J]. AJR,1993,161(2):373-379.
  • 2[3]Hayes CE, Tsuruda JS, Mathis CM, et al. Brachial plexus: MR imaging with a dedicated phased array of surface coils[J]. Radiology, 1997, 203(1):286-289.
  • 3[4]Kuntz C, Blake L, Brize G, et al.Magnetic resonance neurography of pheripheral nerve lesions in the lower extremity[J]. Neurosurgy, 1996, 39()4:750-759.
  • 4[5]Filler AG, Kliot M, Franklyn AH, et al. Application of magnetic resonance neurography in the evaluation of patients with peripheral nerve pathology[J]. J Neurosurg,1996,85(2):299-309.
  • 5[6]Mccarthy M. MRI simplifies diagnosis of peripheral nerve lesions[J]. Lancet, 1996,348(9028): 674.
  • 6[7]Howe FA, Filler AG, Bell BA, et al. Magnetic resonance neurography[J]. Magn Res Med, 1992,28(2):328-338.

共引文献35

同被引文献30

引证文献3

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部