摘要
剩余电流保护装置测试仪的校准目前并无可依据的国家检定规程,文中详细介绍了剩余电流保护装置测试仪的测试原理及校准方法,同时介绍了导通电阻测试仪、绝缘电阻测试仪、回路阻抗测试仪的校准方法。
The calibration of Residual Current Operated Protection Device Tester cannot found the reference in the National Verification Regulation.The article narrates the theory and calibration of Residual Current Operated Protection Device Tester.And,the paper simply introduces the calibration of Continuity Tester ,Insulation Resistance Taster and Loop impedance Tester.
出处
《电子质量》
2008年第11期68-70,共3页
Electronics Quality
关键词
RCD
剩余电流保护装置
校准方法
RCD
Residual Current Operated Protection Device
Calibration Method