摘要 介绍了分级变频软起动器的工作原理,限制电机起动电流的软起动器。这种软起动器对传统软起动器的电路结构进行了改造,通过对晶闸管的控制实现对电压频率的离散控制,即分级变频。经过对子频率的相位研究,采用转矩最大的正序组合并在频率分级起动的同时结合调压起动的方法。最后通过仿真试验,证明了此种分级变频调压软起动器可以有效地提高起动转矩降低起动电流。 In this paper, a Soft starter was developed to improve electromagnetic torque and reduce current at the motor starting. This soft starter improved the traditional circuit structures, the strategy defined the triggering instants of the soft starters SCR to control the discrete frequency of AC power supply. After studying the sub-frequency phases, the positive sequence voltage is proposed, and starting the motor with the surge of start-up at the same time. Finally, simulation tests proved that the frequency of such classification surge soft starter is effective in raising starting torque and reducing starting current.
作者 阎超 石新春
出处 《电力科学与工程》 2008年第10期1-4,共4页 Electric Power Science and Engineering
关键词 分级变频 电机软起动 晶闸管触发 discrete frequency motor soft-starting thyristor trigger
  • 相关文献

参考文献6

  • 1李发海 王岩.电机与拖动基础[M].北京:清华大学出版社,2000..
  • 2Williams A J, Griftith M s. Evaluating the effects of motor starting on industrial and commercial power systems [J]. IEEE Transactions On Industry Applications, 1978, (7): 292-299.
  • 3胡崇岳.现代交流调速技术[M].北京:机械工业出版社,2000..
  • 4Antonio Ginart, Rosana Esteller. High starting torque for AC SCR controller [J]. IEEE Transactions on Energy Conversion, 1999,14 (3).
  • 5许实章.电机学[M].第三版.北京:机械工业出版社,1996.
  • 6佘致廷,肖岸文,董璞,曾聪.基于分级变频高转矩软起动器的研究[J].湖南大学学报(自然科学版),2004,31(6):46-50. 被引量:16

二级参考文献6

  • 1BY J, GEORGE SEGGEWISS,RODNEY G, et al. the prooess economic henefits of synchronizing Applications with medium-voltage drives[J].IEEE Industry applications ,2003,9(4) :58 - 65.
  • 2ANTONIOG, ROSANA E. High starting torque for AC SCR controller[J]. IEEE Trans on Energy Conversion, 1999,14(3):
  • 3NEHRIR M H. Speed control of three-phase induction motor by stator voltage control[J]. IEEE Transactions On Industrial Electronics and Control Instrumentation 1975,5:172-174.
  • 4WILLIAMS A J, GRIFFITH M S. Evaluating the effects of mtor starting on industrial and commercial power systems[J]. IEEE. Transactiros On Industry Applications, 1978,(7):292-299.
  • 5许宏纲,徐方逸.软起动器及其应用[J].电世界,1999,40(5):1-3. 被引量:16
  • 6佘致廷,刘志星,董璞.基于MATLAB/SIMULINK动态仿真模型的高转矩软起动器研究[J].电气传动自动化,2003,25(3):14-17. 被引量:25

共引文献43

同被引文献7

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部