高密度多孔聚乙烯兔眶壁植入后的血管纤维化进程 被引量:2

Fibrovascularization of high-density porous polyethylene implanted into the rabbit's orbit
下载PDF
导出
摘要 目的探讨高密度多孔聚乙烯(high-density porous polyethylene,商品名Medpor)在兔眶壁植入后其血管纤维化进程和特点,为该材料临床应用的有效性与安全性提供理论指导。方法将相同厚度的Medpor修剪成相同大小块状植入兔眶壁,分不同时间点取出做组织学检查与电镜观察,对各时段不同切面、边缘和中央部分纤维化进程进行比较,并做相应统计学分析。所有标本取出后均从中部切开成两半,分别从断面和端面两个切面观察。结果高密度多孔聚乙烯植入11d后,所有标本完全纤维化,各个切面的纤维长入比率随时间推移呈递增趋势。端面边缘和中央纤维化进程差别有统计学意义,断面边缘和中央纤维化进程差别无统计学意义。4周后,各个切面毛细血管密度达到一致。电镜观察植入2周后,材料间隙纤维稀疏,4周后纤维致密。结论通道结构对相应部位的纤维血管化进程有一定的促进作用。高密度多孔聚乙烯植入4周后可以认为其度过临床危险期。 Objective To study the fibrovascularization of high- density porous polyethylene (Medpor) implanted into the rabbit's orbit to provide theoretical guidelines for the clinical application of the material. Methods The Medpor was cut to fit the superior or- hital floor and implanted into the orbital floor. The implanted Med- pors were removed at 2, 5, 8, 11, 14 and 28 days after implan- tation for histological study and removed 1, 2, 4, 6 and 8 weeks after implantation for observation under a scanning electron micro- scope. The density of the fibre and the ratio of fibrovaseularization in different sections and in different parts of sections were calculat- ed for statistical analysis. Each specimen was cut in the middle, and both surfaces of the transection and the butt end were evaluated. Results All specimens were completely fibrated at 11 days after implantation. The fibrovascularization rate gradually increased and there was a statistically significant difference between each interval. There was no statistical difference between the fibovaseular- ization of different parts of the transection, but a statistically sig- nificant difference was found between different parts of the butt end. There was no statistical significance of the fibovascularization difference between the transection and the butt end. Vascularization reached the same levels in the different parts of each section after 4 weeks. Under scanning electron microscopy, fibers were found to be sparse 2 weeks after implantation, while all the pores were full of compact fibres that bio-integrated with the implants after 4 weeks. Conclusion The channel-like structure in the material can accelerate fibovascularization. It can be assumed that the implant has the ability to resist infection and exposure 4 weeks after im- plantation.
出处 《眼视光学杂志》 2009年第1期69-72,共4页 Chinese Journal of Optometry & Ophthalmology
基金 温州市科委基金课题项目(LHZ02046)
关键词 高密度多孔聚乙烯 眼眶 纤维血管化进程 high-density porous polyethylene orbit fibrovascularization rabbit
  • 相关文献

参考文献16

  • 1Bikhazi HB, Van AR. The use of Medpor in cosmetic andrecostructive:Experimental and clinical evidence [M]// Plastic and reconstructive surgery of the head and neck. St Iouis: Mosby, 1990: 271-272.
  • 2Young VL, Schuster RH, Harris LW. lntracerebral hematoma complicating split calvarial bone-graft harvesting [J]. Plast Reconstr Surg, 1990,86(4) :763-765.
  • 3Lin KY, Bartlett SP, Yaremchuk M J, et al. The effect of rigid fixation on the survival of onlay bone grafts:an experimental study[J]. Plast Reconstr Surg, 1990,86(3) :449-456.
  • 4Mauriello JA Jr. Inferior rectus muscle entrapped by Teflon implant after orbital floor fracture repaie [J]. Ophthal Plast Reconstr Surg, 1990,6 (3) : 218-220.
  • 5Bigham WJ. Fibrovascular ingrowth in porous ocular implants: the effect of material composition,porosity,growth factors,and coatings[J]. Ophthal Plast Reconstr Surg, 1999,15(5):317-325.
  • 6Choi JC, Fleming JC, Aitken PA, et al. Porous polyethylene channel implants :a modified porous polyethylene sheet designed for repairs of large and complex orbital wall fractures[J]. Ophthal Plast Reconstr Surg, 1999,15(1):56-66.
  • 7Rubin PA, Popham JK, Bilyk JR, et al. Comparison of fibrovaseular ingrowth into hydroxyapatite and porous polyethylene or bital implants[J]. Ophthal Plast Reconstr Surg, 1994,10(2):96-103.
  • 8Goldberg RE, Dresner SC, Braslow RA. Animal model of porous polyethylene orbital implants[J]. Ophthal Plast Reconstr Surg, 1994,10(2) : 104-109.
  • 9Soparkar CN, Wong JF, Patrinely JR, et al. Porous polyethylene implant fibrovascularizatinn rate is affected by tissue wrapping, agarose coating, and insertion site[J]. Ophthal Plast Reconstr Surg, 2000,16(5) : 330-356.
  • 10Soparkar CN, Wong JF, Patrinely JR, et al. Epidermal and fibroblast growth factors enhance fibrovascular integration of porous polyethylene implants[J]. Ophthal Plast Reconstr Surg, 2000,16(5) :337-340.

二级参考文献4

  • 1郑曰中 张清福等(译).眼科手术图谱[M].天津:天津科学技术出版社,1996.84-100.
  • 2Stanley RB,Mathog RH.Evaluation and correction of combined orbital trauma syndrome[].Laryngoscope.1983
  • 3Sclafani AP,Romo T,Silver L.Clinical and histologic behavior of exposed poroushigh-density polyethylene implants[].Plastic and Reconstructive Surgery.1997
  • 4Peter NN,Patrick S.Advances in the management of orbital fractures[].Clinics in Plastic Surgery.1992

共引文献16

同被引文献19

  • 1姜冬,崔瑞,李丽.Medpor治疗眼球内陷及下陷13例[J].眼科新进展,2004,24(4):326-326. 被引量:3
  • 2何昭燕,惠延年,韩泉洪,王琳,张自峰,韩静.异种脱细胞真皮与异体巩膜作为HA义眼台包裹材料的实验研究[J].中华整形外科杂志,2006,22(3):216-220. 被引量:6
  • 3崔红光,郦惠燕,陈艳红.Medpor义眼座置入同期放置钛钉治疗眼眶凹陷畸形[J].中华创伤杂志,2006,22(6):428-430. 被引量:2
  • 4扈梅,林兆全.4种生物材料大鼠体内生物相容性的对比实验研究[J].新疆医科大学学报,2006,29(5):436-438. 被引量:5
  • 5ANDO F,OHBA N,TOUURA K,HIROSE H. Anatomical and visual outcomes after episcleral macular buckling compared with those after pars plana vitrectomy for retinal detachment caused by macular hole in highly myopic eyes[J]. Retina,2007,27(1):3744.
  • 6DEVIN F,TSUI I,MORIN B, DUPRAT JP,HUBSCHMAN JP. T-shaped scleral buckle for macular detachments in high my- opes[J]. toina,2011,31(1):177-180.
  • 7SOHEILIAN M,GHASEMINKJAD AK,YA2DANI S,AHMADIEH H,AZARMINA M,DEHGHAN MH,et al. Surgical management of retinal detachment in highly myopic eyes with macular hole[J]. Ophthalmic Surg Lasers Imaging,2007,38(1):15-22.
  • 8YAN Z, WANG C,CHEN W,SONG X. Biomechanical consid- erations :evaluating scleral reinforcement materials for patho- logical myopia[J]. Can J Ophthalmol,2010,45(3):252-255.
  • 9RIPANDELU G,PARISI V,FHIBERG TR,COPPE AM , SCAS- SA C, STIRPE M. Retinal detachment associated with macular hole in high myopia: using the vitreous anatomy to optimize the surgical approach[J]. Ophthalmology, 2004,111(4):726-731.
  • 10UN KY,BARTLETT SP,YAREMCHUK MJ,FALLON M,GROSS- MAN RF,WHITAKER LA. The effect of rigid fixation on the survival of onlay bone grafts[J]. Plast Reconstr Surg,1990, 86(3):449-456.

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部