新型肝素铁抗凝血涂层修饰血管内支架 被引量:8

Novel iron heparin anticoagulation coating for intravascular stents
下载PDF
导出
摘要 实验于2006-12/2008-01在哈尔滨工业大学纳米医药与生物传感器实验室完成。采用静电吸引层层自组装的方法,在Ni-Ti合金表面组装Fe3+/肝素多层薄膜,使得材料表面形成稳定的糖铁络合物涂层。紫外可见光光度计、原子力显微镜和傅里叶变换红外光谱证实了Fe3+/肝素能够在Ni-Ti合金表面上交替沉积形成均匀的多层膜,并且具有很好的稳定性。研究表明,溶液的pH值和离子强度的增加能够显著增加涂层的增长速度。凝血酶失活、部分活化凝血酶原时间、溶血和血小板黏附试验等则证实了涂层具有良好的抗凝血性能和血液相容性,肝素并没有因与Fe3+结合而降低其抗凝血活性。说明该涂层可以用作血管内支架材料的表面修饰改性,在支架置入早期阻止血栓形成。 The experiment was performed at Nanomedicine and Biosensor Laboratory of Harbin Institute of Technology from December 2006 to January 2008. Fe3+/heparin multilayer films were assembled on the surface of Ni-Ti alloy by the layer-by-layer self-assembly, which made the stable glucose-Fe complex coating form on the surface of Ni-Ti alloy. The ultraviolet-visible absorption spectrophotometry, atomic force microscopy and fourier transform infrared spectroscopy proved that the Fe3+/heparin could form uniform multilayer films by alternative deposition on the surface of Ni-Ti alloy, and the coating had good stability. Studies showed that the increase of pH value and ionic strength in solution could obviously improve the increasing speed of the coating. The coating had good anticoagulation property and blood compatibility, which were proved by detection of thrombin inactivation, activated partial thromboplastin time, hemolysis test and platelet adhesion test. The heparin did not decrease its anticoagulation property after combined with Fe3+. The results suggested that the coating could be use for the surface modification of intravascular stents, and prevent thrombosis forming in early stage of stent implantation.
机构地区 哈尔滨工业大学
出处 《中国组织工程研究与临床康复》 CAS CSCD 北大核心 2008年第48期9478-9480,共3页 Journal of Clinical Rehabilitative Tissue Engineering Research
基金 国家自然科学基金资助项目(NSFC-50573015) 新世纪优秀人才支持计划资助项目(NCET-05-0335)~~
  • 相关文献

参考文献23

  • 1Koster R, VielufD, Kiehn M, et al. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 2000: 356(9245): 1895-1897
  • 2Wataha JC, Lockwood PE, Marek M, et al. Ability of Ni-containing biomedical alloys to activate monocytes and endothelial cells in vitro. J BiomedMaterRes 1999,45(3): 251-257
  • 3Liu JX, Yang DZ, Wang WQ, et al. Gongneng Cailiao 2000: 31(6): 584-586
  • 4刘敬肖,杨大智,王伟强,陈吉华,蔡英骥.管腔内支架用金属材料的生物相容性及其表面改性[J].功能材料,2000,31(6):584-586. 被引量:13
  • 5Haude M, Konorza TF, Kalnins U, et al. Heparin-coated stent placement for the treatment of stenoses in small coronary arteries of symptomatic patients. Circulation 2003; 107(9): 1265-1270
  • 6Tan Q, Ji J, Barbosa MA, et al. Constructing thromboresistant surface on biomedical stainless steel via layer-by-layer deposition anticoagulant. Biomaterials 2003: 24(25): 4699-4705
  • 7Choi J, Bogdanski D, Koller M, et al. Calcium phosphate coating of nickel-titanium shape-memory alloys. Coating procedure and adherence of leukocytes and platelets. Biomaterials 2003,24(21): 3689-3696
  • 8Galeska I, Chattopadhyay D, Moussy F, et al. Calcification-resistant Nafion/Fe^3+ assemblies for implantable biosensors. Biomacromolecules 2000, 1(2): 202-207
  • 9Liu M, Yue X, Dai Z, et al. Stabilized hemocompatible coating of nitinol devices based on photo-cross-linked alginate/heparin multilayer. Langmuir2007; 23(18): 9378-9385
  • 10Haude M, Konorza TF, Kalnins U, et al. Heparin-coated stent placement for the treatment of stenoses in small coronary arteries of symptomatic patients. Circulation 2003,107(9):1265-1270

二级参考文献36