不同测量条件对兔正常眼压测量值的影响 被引量:3

Different condition on measure results of rabbit intraocular pressure
下载PDF
导出
摘要 目的探讨不同的测量条件对正常眼压基线测量的影响。方法应用Tono-PenTM-XL眼压计测量新西兰兔100只(200眼)的眼压值。测量分别在3种条件下进行:条件1:将兔放入布袋中,仅露出头部,角膜表面麻醉下,操作者用手指轻轻分开兔的眼睑,即可进行眼压测量;条件2:将兔的身体用布裹紧,仅露出头部,检查者将包紧的兔平放在双腿上,用手臂压住,角膜表面麻醉下,用手指扒开兔的眼睑,进行眼压测量;条件3:全麻联合角膜表面麻醉下测量眼压。结果(1)条件1时兔眼压值为6.5~14.5mmHg(1kPa=7.5mmHg),平均(9.7±2.9)mmHg,符合对数正态分布(W:Normal=0.9756,P=0.1095);(2)条件2时兔眼压值为11.0~20.0mmHg,平均(14.8±4.1)mmHg,高于条件1时所得结果,差异具有显著统计学意义(P=0.0003);(3)条件3时兔眼压值为5.0~11.0mmHg,平均(7.8±2.8)mmHg,低于条件1时所得结果,差异有显著统计学意义(P=0.001)。结论新西兰兔清醒状态下眼压基线为(9.7±2.9)mmHg。眼压测量过程中操作粗鲁和全身麻醉都会影响兔眼压测量的准确性。 Objective To investigate the influence of different conditions on measure results of rabbit normal intraocular pressure (IOP). Methods IOP of 100 New Zealand rabbits ( 200 eyes) were measured by Tono-PenTM-XL. The measurement was done under 3 different conditions. Condition 1 :Put rabbit into a bag,left head outside. Under cornea surface anaesthesia, manipulator opened the eye lids slightly with fingers. IOP measure was done easily. Condition 2 : Wrapped rabbit tightly with cloth, left head outside. Put being wrapped rabbit on the knee, pressed with arm. Under cornea surface anaesthesia, manipulator opened the eye lids forcibly with fingers to measure IOP. Condition 3 :Under general and cornea surface anaesthesia, IOP measure was done. Results Under condition 1, average IOP was (9.7 ± 2.9 ) mmHg ( 1 kPa = 7.5 mmHg, 5.5 - 14.5 mmHg), which accorded with log-normal distibution ( W: Normal = 0. 975 6, P = 0. 109 5 ). Under condition 2, average IOP was ( 14.8 ± 4.1 ) mmHg( 11.0 - 20.0 mmHg), which was higher than that under condition 1 (P = 0.000 3 ). Under condition 3, average IOP was ( 7.8 ±2.8 ) mmHg ( 5.0 - 11.0 mmHg), which was lower than that under condition 1 (P = 0. 001 ). Conclusion The IOP baseline of conscious New Zealand rabbit is (9.7 ± 2.9) mmHg. Crude action and general anaesthesia can affect the precision of 10P measurement.
出处 《眼科新进展》 CAS 北大核心 2009年第1期35-37,共3页 Recent Advances in Ophthalmology
关键词 正常眼压 测量条件 麻醉 normal intraocular pressure rabbit measure condition anaesthesia
  • 相关文献

参考文献12

  • 1乔荣华,刘丽娜,李美玉,任泽钦.Tono-Pen眼压计临床应用评价[J].中国实用眼科杂志,2004,22(12):980-982. 被引量:12
  • 2Abrams LS, Vitale S, Jampel HD. Comparison of three tonometers for measuring intraocular pressure in rabbits [ J ]. Invest Ophthalmol Vis Sci 1996;37(5) :940-944.
  • 3Lim KS, Wickremasinghe SS, Cordeiro MF, Bunce C, Khaw FT. Accuracy of intraocular pressure measurements in New Zealand white rabbits [J]. Invest Ophthalmol Vis Sci 2005;45 (7) :2419- 2423.
  • 4张虹,李贵刚,胡军,胡维琨,孙旭芳,赵春明.Tono-Pen眼压计对兔眼不同部位眼压测量值的相关性研究[J].眼科新进展,2006,26(10):744-746. 被引量:6
  • 5Nagdeve NG, Yaddanapudi S, Pandav SS. The effect of different doses of ketamine on intraocular pressure in anesthetized children[ J ]. J Pediatr Ophthalmol Strabismus 2006 ; 43 ( 4 ) : 219- 223.
  • 6Artru AA. Trabecular outflow facility and formation rate of aqueous humor during propofol anesthesia in rabbits [ J ]. Anesth Analg 1993 ;77 ( 3 ) :564-569.
  • 7Artru AA. Trabecular outflow facility and formation rate of aqueous humor during intravenous cocaine or lidocaine in rabbits [ J]. Anesth Analg 1994 ;78 ( 5 ) :889-896.
  • 8Artru AA, Momota Y. Trabecular outflow facility and formation rate of aqueous humor during anesthesia with sevoflurane-nitrous oxide or sevoflurane-remffentanil in rabbits [ J ]. Anesth Analg 1999;88(4) :781-786.
  • 9Lentschener C, Leveque JP, Mazoit JX, Benhamou D. The effect of pneumoperitoneum on intraocular pressure in rabbits with alpha-chymotrypsin-induced glaucoma[ J]. Anesth Analg 1998 ; 86 (6) :1283-1288.
  • 10Jia L, Cepurna WO, Johnson EC, Morrison JC. Effect of general anesthetics on IOP in rats with experimental aqueous outflow obstruction [ J]. Invest Ophthalmol Vis Sci 2000;41 ( 11 ) :3415- 3419.

二级参考文献13

  • 1Minckler DS et al. Am J Ophthalmol, 1987, 104:168
  • 2Khan JA et al. Arch Ophthalmol, 1991, 109:1444
  • 3Frenkel REP et al. Arch Ophthalmol, 1988, 106:750
  • 4申尊茂,李子良,谢立信主编.眼科新编.第1版.人民卫生出版社,1991,112
  • 5HessemerVetal. AmJOPhthalmol, 1988, 105:678
  • 6Boothe WA et al. Arch Ophthalmol, 1988, 106:1214
  • 7Denis P et al. Ophthalmologica, 1993, 207:155
  • 8Khan JA,Davis M,Graham CE,Trank J,Whitacre MM.Comparison of Oculab Tono-Pen readings obtained from various corneal and scleral locations[J].Arch Ophthalmol 1991; 109(10):1444-1446.
  • 9Kooner KS,Cooksey JC,Barron JB,Zimmerman TJ,Gupte RK,Wall JL,et al.Tonometry comparison:Goldmann versus Tono-Pen[J].Ann Ophthalmol 1992; 24(1):29-36.
  • 10Frenkel RE,Hong YJ,Shin DH.Comparison of the TonoPen to the Goldmann applanation tonometer[J].Arch Ophthalmol 1988;106(6):750-753.

共引文献15

同被引文献52

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部