期刊文献+

长光程空气质量自动监测仪原理及常见问题浅析 被引量:3

Analysis and treatment of common problems in long-path air automatic monitoring
下载PDF
导出
摘要 长光程空气质量自动监测仪是用来监测大气中各种污染物含量的专用仪器,采用国家环保部认可和美国环境保护署(USEPA)推荐的方法,利用光学差分吸收光谱技术研制而成,差分吸收光谱(DOAS,Differential Optical Absorption Spectroscopy)技术国外已广泛用于环境监测,国内也已形成产业。我站引入国产长光程系统(安徽铜陵)开展污染气体(SO2、NO2)24小时连续监测。本文就我站在使用国产长光程大气监测系统过程中出现的一些常见问题进行剖析,以供参考。 There are composed of lots of parts and complicated construction in the long - path air automatic monitoring system, the running substations is supervised and controlled by master station through the on - line way, therefore it is difficult to diagnose and exclude break downs the system caused. This paper is to help the operators deepen their comprehension for the system and improve the skill in excluding the abnormal data through diagnosing and analyzing the abnormal data from the master station.
出处 《江西化工》 2008年第4期238-241,共4页 Jiangxi Chemical Industry
关键词 空气质量监测 长光程 常见问题 分析处理 environmental air monitoring DOAS common problems analysis treatment
  • 相关文献

参考文献4

二级参考文献9

  • 1国家环保局.空气和废气监测分析方法[M].北京:中国环境科学出版社,1990..
  • 2[1]Platt U,Perner D. Direct measurements of atmospheric CH2O, O3, NO2 and SO2 by differential optical absorption in the near UV[J]. Journal of geophysical research, 1980, 85(12): 7453~7458.
  • 3[2]Axelsson H, Eilard A, Emanuelsson A et al. Measurement of aromatic Hydrocarbons with the DOAS technique[J]. Applied spectroscopy, 1995, 49(9): 1254~1260.
  • 4[3]Andy R. Reisinger, Unidentified interference in DOAS Measurements of ozone[J]. Applied spectroscopy, 2000, 54(1): 72~78.
  • 5[4]Kourtidis K,Ziomas I, Zerefos C et al. Benzene and toluene levels measured with a commercial DOAS system in Thessaloniki[J]. Greece, Atmospheric environment, 2000, 34: 1471~1480.
  • 6OPSIS AB. EnviMan ComVisioner Configuration Manual (Version 1.0)CM]. Sweden : ] 999.
  • 7John M C Plane,Chia-Fu Nien.Differential optical absorption spectrometer for measuring atmospheric trace gases[].The Review of Scientific Instruments.1992
  • 8Platt U,Perner D.Simultaneous measurements of atmospheric CH2 O,O3 and NO2 by differential optical absorption[].Journal of Geophysical Research.1979
  • 9Platt U,Perner D.Direct measurements of atmospheric CH2 O,HNO2 , O3 and SO2 by differential absorption in the near UV[].Journal of Geophysical Research.1980