摘要 氯离子是影响水中化学需氧量测定结果准确性的主要干扰因素。当废水中氯离子浓度在2000~8000mg/L时,采用以氯离子浓度为横坐标,其干扰产生的化学需氧量值为纵坐标绘制标准曲线的方法,测定氯离子影响化学需氧量值,用重铬酸钾法的测定值减去氯离子的影响值,得到实际样品的化学需氧量,结果令人满意。 The chloride ion is the main interference factors that affect the water chemical oxygen demand determining result accuracy. When chloride ion concentration in waste water is at 2 000 - 8 000 mg/L, adopts chloride ion concentration as the x-coordinate, the value of chemical oxygen demand by its disturbance as the y-coordinate, to determine the chlorine ion affecting chemical oxygen demand value by drawing the standard curve, and then with the determining value given by dichromate method minus the influence value of chloride ion, the chemical oxygen demand of actual sample is obtained and the results are satisfactory.
出处 《环境保护与循环经济》 2009年第1期38-39,共2页 environmental protection and circular economy
关键词 重铬酸钾法 化学需氧量 氯离子影响 标准曲线 dichromate method chemical oxygen demand affects of chloride ion standard curve
  • 相关文献

参考文献2

共引文献17

同被引文献11

  • 1王方园,盛贻林,郑绍成.高浓度氯离子化工废水中COD测定方法比较[J].工业水处理,2006,26(5):72-74. 被引量:20
  • 2DL/T938-2005,火电厂排水水质分析方法[S].北京:中国电力出版社,2005.
  • 3DIMT997-2006,火电厂石灰石一石膏湿法脱硫废水水质控制指标[S].北京:中国电力出版社,2006.
  • 4HJ/T70-2001,高氯废水化学需氧量的测定氯气校正法[S].北京:中国环境科学出版社,2001.
  • 5HJ/T132-2003,高氯废水化学需氧量的测定碘化钾碱性高锰酸钾法[S].北京:中国环境科学出版社,2003.
  • 6GB11901-89,水质悬浮物的测定重量法[S].北京:中国标准出版社,1989.
  • 7GB11896-89,水质氯化物的测定硝酸银滴定法[S].北京:中国标准出版社,1989.
  • 8GB11914-89,水质化学需氧量的测定重铬酸盐法[S].北京:中国标准出版社,1989.
  • 9凌建军,曹国中,蒋薇,赵东霞,汪文丽,崔顺斌.河南桑坡村皮毛加工废水治理改扩建工程[J].中国给水排水,2008,24(14):72-75. 被引量:4
  • 10黄林生.重铬酸钾法测定高氯废水中化学需氧量的方法探讨[J].化学工程与装备,2009(5):146-147. 被引量:3