期刊文献+

Determination of trace mercury in compost extract by inhibition based glucose oxidase biosensor 被引量:1

Determination of trace mercury in compost extract by inhibition based glucose oxidase biosensor
下载PDF
导出
摘要 A novel inhibition based biosensor of glucose oxidase(GOx) for environmental mercury detection was developed. An electropolymerized aniline membrane was prepared on a platinum electrode containing ferrocene as electron transfer mediator, on which GOx was cross-linked by glutaraldehyde. The response of the sensor was based on the current reduction in the electrochemical system by inhibition of mercury against GOx electrode. The detection limit of the inhibition-based sensor for mercury is 0.49 μg/L, and the linear response ranges are 0.49-783.21 μg/L and 783.21 μg/L-25.55 mg/L. The GOx membrane can be completely reactivated after inhibition, and remains 70% of the activity in more than one month. The sensor was used for mercury determination in compost extract with good results. A novel inhibition based biosensor of glucose oxidase(GOx) for environmental mercury detection was developed. An electropolymerized aniline membrane was prepared on a platinum electrode containing ferrocene as electron transfer mediator, on which GOx was cross-linked by glutaraldehyde. The response of the sensor was based on the current reduction in the electrochemical system by inhibition of mercury against GOx electrode. The detection limit of the inhibition-based sensor for mercury is 0.49 μg/L, and the linear response ranges are 0.49 783.21 gg/L and 783.21 μg/L-25.55 mg/L. The GOx membrane can be completely reactivated after inhibition, and remains 70% of the activity in more than one month. The sensor was used for mercury determination in compost extract with good results.
出处 《中国有色金属学会会刊:英文版》 EI CSCD 2009年第1期235-240,共6页 Transactions of Nonferrous Metals Society of China
基金 Project(50608029) supported by the National Natural Science Foundation of China Project(2004AA649370) supported by the Hi-tech Research and Development Program of China Project(2005CB724203) supported by the National Basic Research Program of China Project(IRT0719) supported by the Program for Changjiang Scholars and Innovative Research Team in University of China
关键词 有色金属 金属学 性能参数 分析 mercury inhibition glucose oxidase biosensor compost
  • 相关文献

参考文献2

二级参考文献1

  • 1Liu C C,Bioelectrochem Bioenerg,1981年,8卷,703页

共引文献5

同被引文献27

  • 1TROJANOWICZ M,KRAWCZYSKIN V E L,KRAWCZYK T,GESCHKE O,CAMMANN K.Biosensors based on oxidases immobilized in various conducting polymers. Sensors and Actuators . 1995
  • 2GROS P,DURLIAT H,COMTAT M.Use of polypyrrole film containing Fe (CN)63-as pseudo reference electrode:application for amperometric biosensor. Electrochemica Acta . 2000
  • 3DANZER T,SCHWEDT G.Multivariate evaluation of inhibition studies on an enzyme electrodes system with pesticides and mixtures of mercury and pesticides. Analytica Chimica Acta . 1996
  • 4KURALAY F,OZYORUK H,YILDIZ A.Inhibitive determination of Hg2+ion by an amperometric urea biosensor using poly (vinylferrocenium)film. Enzyme and Microbial Technology . 2007
  • 5Ozkan M,Erhan E,Terzi ?,Tan, ?,?z?ner, ?. K.Thermostable amperometric lactate biosensor with clostridium thermocellum lactate dehydrogenase for measurement of blood lactate. Talanta . 2009
  • 6CONTAG P R,WILLIAMS M G,ROGERS P.Cloning of lactate dehydrogenase from Clostridium acetobutylicum B463and expression in Escherichia coli. Applied and Environmental Microbiology . 1990
  • 7SHEKHOVTSOVA T N,CHERNETSKAYA S V,BELKOVA N V,DOLMANOVA I F.The use of immobilised enzymes for the determination of metal ions. Journal of Analytical Chemistry . 1994
  • 8ASSA P,ZKAN M,ZCENG-Z G.Thermostability and regulation of Clostridium thermocellum L-lactate dehydrogenase expressed in Escherichia coli. Annals of Microbiology . 2005
  • 9OZKAN M,YILMAZ E,LYND L R,OZCENG-Z G.Cloning and expression of the Clostridium thermocellum L-lactate dehydrogenase gene in Escherichia coli and enzyme characterization. Canadian Journal of Microbiology . 2004
  • 10HALLIWELL C M,SIMON E,TOH C S,BARTLETT P N,CASS A E G.Immobilisation of lactate dehydrogenase on poly (aniline)-poly (acrylate)and poly (aniline)-poly (vinyl sulphonate)films for use in a lactate biosensor. Analytica Chimica Acta . 2002

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构