摘要 采用ANSYS软件建立了非线性有限元分析计算模型,对侧板加强式梁柱节点的抗震性能进行了研究,分析了侧板长度对连接性能的影响。结果表明,侧板加强节点滞回性能优于普通无侧板节点,节点承载力也大大提高。侧板加强节点滞回曲线稳定、饱满,这种连接表现出了较好的耗能能力。 Utilizing the software ANSYS, the seismic performances of beam-column connections with side plate reinforced beam flanges are analyzed. The results show that, beam-column connections of steel structures with side plate reinforced beam flanges have better dissipative capacities, stabilized and fullness curves of cycle loading, also good performance and high bearing capacities.
作者 黄艳 刘新春
出处 《建筑结构》 CSCD 北大核心 2009年第2期28-30,共3页 Building Structure
关键词 侧板 梁柱刚性节点 滞回性能 有限元分析 side plate beam-column connections rigid connection finite element analysis
  • 相关文献

参考文献6

二级参考文献5

  • 1Recommended Seismic Design Criteria for New Steel Moment-frame Buildings. FEMA 3.50,2000,7.
  • 2Nestor lwankiw, Sergio Zoruba. Steel moment frames: resolution of recent seismic detailing and material shape issues. Journal of constructional steel research,2002,58.
  • 3Tamboll A R, Fasce P E. Handbook of Structural Steel Connection Design and Details. McGraw-Hill, 2000.
  • 4Egor Paul Popov,Keynote Paper in ICASS’96,1996年
  • 5JGJ 99-1998.高层民用建筑钢结构技术规程[S],1998.