期刊文献+

测定水样中化学需氧量的不确定度 被引量:1

Evaluation on the Uncertainty of COD Determination in Aqueous Medium
下载PDF
导出
摘要 对化学需氧量测定的不确定度进行合理评定,应充分考虑测定过程中的不确定度来源。建立了重铬酸钾法测定水样中化学需氧量不确定度的数学模型,对组成化学需氧量的各个因子的不确定度分量进行了详尽的分析和计算,得出了本次样品CODCr的测定结果为72.2mg/L,扩展不确定度为3.8mg/L。 The sources of uncertainty during measuring process should be fully considered when evaluating the uncertainty of COD determination in aqueous medium.We established a mathematical model of the uncertainty of COD determination by potassium dichromate(K2Cr2O7)method,and then the uncertainty of COD determination were analyzed and calculated in detail for all factors which compose COD.The results showed the COD of the water sample was 72.2 mg/L,and the expanded uncertainty was 3.8 mg/L.
出处 《油气田环境保护》 CAS 2009年第1期57-59,共3页 Environmental Protection of Oil & Gas Fields
关键词 水样 测定 化学需氧量 不确定度 water sample chemical oxygen demand measurement uncertainty
  • 相关文献

参考文献2

  • 1中华人民共和国国家计量技术规范编写委员会.测量不确定度评定与表示.北京:中国计量出版社,1999.
  • 2国家质量技术监督局技量司.测量不确定度评定与评定表示指南.北京:中国计量出版社,2005.

共引文献1

同被引文献8

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部