建筑给水超压出流会造成水的隐形浪费。据此,该试验选择典型建筑,在支管安装减压阀,进行对比试验。并在实施改造后,结合各种影响因素,根据试验所得数据,分析得出节水效果,以及其效益与特点。以期通过该试验对存在超压出流建筑的改造提供参考。
Architectural high-pressure water can cause unnoticable waste of water.Therefore, our test select a typical construction,and install pressure reducing valves in the branch pipes.After the implementation of the transformation,and considering all influencing factors,then analyse the experimental data to get the watersaving effects,as well as its benefits and features.Our test is in order to offer some useful advices to the constructions with high-pressure of water.
出处
《给水排水》
CSCD
北大核心
2010年第S1期311-313,共3页
Water & Wastewater Engineering
关键词
超压出流
建筑节水
减压
Overpressure out the flow
Building water-saving
Decompression