摘要
目的:加强透析室消毒措施,确保透析安全,预防感染,提高医疗护理质量。方法:透析机:血液透析治疗后,在未进行化学消毒之前,用酸性氧化电位水对透析机快速接口内面、表面以及透析机上快速接口的连接器表面进行擦拭消毒;机器表面使用酸性氧化电位水擦拭;病历牌:血液透析治疗后,用酸性氧化电位水表面进行擦拭消毒。对采取措施前后的检测结果进行比较。结果:采取加强措施后,透析机快速接口进、出液口液体细菌检测菌落数低于未采取措施时,P<0.01。病历牌表面细菌计数均低于未采取措施时,P<0.01。结论:采取酸性氧化电位水加强透析室日常消毒,能够降低菌落数,保证透析液最佳的微生态品质,确保透析安全;减少病历牌表面的细菌数量,预防病历牌成为医院感染的传播途径;减少消毒制剂对于透析机产生的腐蚀及对人体的刺激的同时降低医疗成本。
Objective: Use the acidic electrolyzed oxidizing water (EOW) as disinfector to insure dialysis safe, prevent infection and promote medical quality. Method: Dialyzer: After hemodialysis, the EOW was used to clean dialyzer machine’s surface, quick mouthpiece inner face, surface and connector surface before any chemical disinfection. Medical records: To disinfect medical records use acidic EOW after hemodialysis. Finally compare effects before and after taking these steps. Results: The amount of bacteria both on dialyzer quick mouthpiece fluid and on medical records were lower after disinfection with acidic EOW (P〈0.01) Conclusion: Applying acidic EOW to daily disinfect in dialysis room can decrease bacteria amount, insure dialysis safe, prevent medical records hospital onset of infection., and also can lessen corrosion to machine, stimulation to people and simultaneously reduce medical cost.
出处
《中国护理管理》
2009年第4期16-18,共3页
Chinese Nursing Management
关键词
透析机
消毒措施
酸性氧化电位水
dialyzer
disinfect
acidic electrolyzed-oxidizing water.