期刊文献+

碳糊电极示波极谱法测定血液中的铜锌

Determination of Zinc and Copper in Human Blood by Oscillopolarography with A Carbon Paste Electrode
原文传递
导出
摘要 研究了用碳糊电极示波极谱阳极溶出法在同一系统中测定血液中的微量锌和铜。测定了36例建康成人血中铜锌的含量,铜锌平均测定值分别为1.05μg/ml和1.40μg/ml。方法的线性关系:铜为0.02~5μg/ml;锌为0.05~6μg/ml。方法具有较好的重现性和准确性。 Copper and zinc in blood in 36 normal people could be determined simutaneously by anodic stripping of oscillopolarography with a carbon paste electrode. This mothod showed a good linear relation:copper of 0.02 ̄5 μg/ml, and zinc of 0.05 ̄6 μg/ml. The average contents of copper and zinc were 1.05 μg/ml and 1.40 μg/ml respectively. This method proved itself to be a better reproducibility and accuracy.
出处 《湖北医科大学学报》 1998年第2期112-114,共3页
基金 湖北省科委基金
关键词 碳糊电极 血清诊断 示波极谱法 MeSH carbon paste electrode polarograph copper zinc/AN
  • 相关文献

参考文献6

二级参考文献11

  • 1刘利娟,丁雄,唐玲,何聿忠,林文业,罗建惠.锌、镉与儿童中枢神经系统疾病51例分析[J].微量元素与健康研究,1994,11(4):59-59. 被引量:5
  • 2周健英,王永博,王丽莉,吴玉洁,张寿松.微分电位溶出法测定血液中锌含量[J]临床检验杂志,1990(01).
  • 3朱海年.微量元素与健康[M]北京大学出版社,1989.
  • 4Zhao Jin,Jiang Shougui,Chen Shikun,Jiang Desen,D. Chakraborti. Direct determination of lead in human blood and selenium, cadmium, copper, zinc in serum by electrothermal atomic absorption spectrophotometry using Zeeman effect background correction[J] 1990,Fresenius’ Journal of Analytical Chemistry(8):877~881
  • 5马贵林.微量元素铜的生理功能与临床儿科[J]医师进修杂志,1984(11).
  • 6孔祥瑞.微量元素与内分泌[J]国外医学内分泌学分册,1982(03).
  • 7毕建忠,李大年,高海青,李心河,刘少平,马中亮,夏洪印.脑梗塞患者血清微量元素(锌、铜、镉、铅、铷、锶)含量变化与临床关系的探讨[J]临床神经病学杂志,1988(02).
  • 8毛筱芬,朱长文,赵贤美.45例肺心病患者血清铜锌铅镉的测定[J].徐州医学院学报,1990,10(3):172-176. 被引量:6
  • 9方明,谭力.南京地区正常人和病人血中十一种元素含量的测定[J].营养学报,1990,12(1):28-35. 被引量:9
  • 10李桂芬,徐健,王欣.血清铜铁锌镁对肝癌诊断和预后的价值[J].临床肝胆病杂志,1991,7(1):43-46. 被引量:8

共引文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部