期刊文献+

新型反渗透阻垢剂动态评价方法的研究 被引量:5

Research of the dynamic evaluation method for RO inhibitors
下载PDF
导出
摘要 提出一种新型"梯级加药法"用于动态评价反渗透阻垢剂。以梯级加药的方式提升进料水的离子含量,通过平台期成垢离子的浓度变化判断阻垢剂的性能。对方法的原理和参数做一定的分析,并通过实验对进口阻垢剂PTP0100、ASD200以及国内某高校研制的#1RO阻垢剂进行对比。试验表明,该方法快速、简便,在阻垢剂投加质量浓度为3 mg/L时,参与评价的阻垢剂性能高低排序依次为:#1RO国产、PTP0100、ASD200。 A new dynamic evaluation method named "step join" for scale inhibitors used in reverse osmosis systems is put forward. The ion-content of the feeding water is increased by the step join method. The change of scaled ion concentration are used for judging the performance of the scale inhibitor. The principle and parameters of the method is analyzed. The imported scale inhibitors PTP0100 and ASD200 and China-made scale inhibitor #1RO are compared by tests. The results show that this method is rapid, simple and convenient. When the dosage is 3 mg/L, among the three kinds of scale inhibitors, #1RO is the best one, and PTP0100 is better than ASD200.
出处 《工业水处理》 CAS CSCD 北大核心 2009年第4期79-81,共3页 Industrial Water Treatment
关键词 反渗透 阻垢剂 评价方法 reverse osmose scale inhibitor evaluation method
  • 相关文献

参考文献9

  • 1周柏青,徐厚道,李芹,李志军.反渗透系统专用阻垢剂的评价方法[J].华北电力技术,2005(4):43-45. 被引量:17
  • 2Butt F H, Rahman F, Duruthamal U, et aL Pilot plant evaluation of advanced vs conventional scale inhibitor for RO desalination [J]. Desalination, 1995,103 (2):189-198.
  • 3Al-Shammiri M, Safar M, Al-Dawas M. Evaluation of two different antiscalants in real operation at the Doha research plant[J]. Desalination, 2000,128( 1 ):1-16.
  • 4Hasson D, Drak A, Semiat R. Inception of CaSO4 scaling on RO membranes at various water recovery levels [ J ]. Desalination, 2001,139(1 ):73-81.
  • 5Pervov A G. A simplified RO process design based on understanding of fouling mechanisms [J ]. Desalination, 1999,126 (1-3): 227-247.
  • 6周伟生,吕勇,齐登谷.反渗透膜用阻垢剂的实验室评价[J].工业水处理,2005,25(11):16-18. 被引量:6
  • 7Dark A, Glucina K, Busch M, et al. Laboratory technique for predicting the scaling propensity of RO feed waters [J]. Desalination, 2000,132( 1-3):233-242.
  • 8张冰如,欧阳清华,李风亭.快速评价反渗透专用阻垢剂阻垢性能的实验技术[J].膜科学与技术,2004,24(6):38-43. 被引量:16
  • 9Drela I, Falewicz P, Kuczkowska S. New rapid test for evaluation of scale inhibitors [ J ]. Water Research, 1998,32 ( 10 ) :3188-3191.

二级参考文献11

  • 1RautenbachR.膜工艺-组件和装置设计基础[M].北京:化学工业出版社,1999.138-139.
  • 2刘茉娥.膜分离技术[M].北京:化学工业出版社,2000.1.
  • 3Darton E G. Membrane chemical research:Centuries apart [J]. Desalination,2000,132:121 - 131.
  • 4Butt F H,Rahman F,Baduruthamal U. Pilot plant evaluation of advanced vs. conventional scale inhibitors for RO desalination[J]. Desalination, 1995,103:189 - 198.
  • 5Al- Shammiri M, Safar M, Al - Dawas M. Evaluation of two different antiscalants in real operation at Doha Research Plant[J ]. Desalination, 2001,28: 1 - 16.
  • 6Pervov A G. Scale formation prognosis and cleaning procedure schedules in reverse osmosis systems operation [ J ].Desalination, 1991,83:72- 118.
  • 7Pervov A G. A simpliued RO process design based on understanding of fouling mechanisms:Scale formation prognosis and cleaning procedure schedules in reverse osmosis systems operation[ J ]. Desalination, 1999,126: 227 - 247.
  • 8张青,吴文辉.临界pH在阻垢剂研究中的应用[J].工业水处理,1997,17(1):33-34. 被引量:23
  • 9陈文瑾,李焱,曾祥钦.静态阻垢法在阻垢剂研究中的改进[J].贵州工业大学学报(自然科学版),1999,28(3):43-47. 被引量:13
  • 10何建军.反渗透系统的运行维护探析[J].工业水处理,2002,22(5):49-52. 被引量:7